My WebLink
|
Help
|
About
|
Sign Out
Home
8D Consent 2007 1001
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2007
>
Packet 2007 1001
>
8D Consent 2007 1001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2007 9:49:36 AM
Creation date
9/28/2007 9:48:27 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
1/10/2007
Retention
PERM
Document Relationships
_CC Agenda 2007 1001
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1001
3A Public Hearing 2007 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1105
Reso 2007-130
(Reference)
Path:
\City Clerk\City Council\Resolutions\2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(b) Automatic sprinkler systems shall be installed and maintained in operable condition <br />as specified in this Article and NFPA Standard l 3, in all buildings or structures. <br />I . Of all occupancy classifications except R3 (single-family and duplex) of type <br />IIN, II-1 hour, IIN, IV, V-1 hour or VN construction, the total floor are of <br />which exceeds 7,500 square feet, irrespective of separation walls. <br />2. Of all occupancy classifications, except R3 (single-family and duplex) of type <br />1 or II -fire resistive construction, the total #loor area of which exceeds <br />10,000 square feet, irrespective of separation walls <br />Of all occupancy classification, irrespective of construction type, the overall <br />height of which exceeds 45 feet. Building height shall be determined in <br />accordance with the Building Code. <br />(c) The provisions of this section shall apply to existing buildings or structures when, <br />over any three year period,: <br />1) Permits for additions and alterations increase the floor area by 25 percent. <br />2) Permit valuation for additions, alterations, repairs or other modifications, <br />individually or cumulatively, ex:;eeds 25 percent of building valuation as <br />determined by the building official. <br />(d) Automatic sprinkler systems installed within buildings, except R-3 occupancies, shall <br />have all control valves and flow devices electrically supervised and maintained by an <br />approved Central Alarm Station, as outlined in NFPA 72. Buildings in existence <br />upon the effective date of this subsection shall be made to conform to the provisions <br />herein within one year from said effective date. <br />Section 7-5-145: MULTIPLE HAZARDS: OUTDOOR STORAGE. <br />(a) When a hazardous material has multiple hazards, all hazards shall be addressed <br />and controlled in accordance with the provisions of this chapter. When overhead <br />noncombustible construction is provided for sheltering exterior hazardous material <br />storage areas, such storage shall not be considered indoor storage when all of the <br />following conditions are met: <br />(I) Supports shall be of noncombustible construction. <br />(2) Supports and walls shall not obstruct more than 25 percent of the <br />perimeter of the storage area. <br />(3) The distance to buildings, property lines, streets, alleys, public ways or <br />exits to a public way shall not be less than the distance required for an <br />exterior hazardous material storage area without weather protection. <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.