My WebLink
|
Help
|
About
|
Sign Out
Home
Reso 2007-130
CityHall
>
City Clerk
>
City Council
>
Resolutions
>
2007
>
Reso 2007-130
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2008 2:06:17 PM
Creation date
10/8/2007 9:51:48 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Resolution
Document Date (6)
10/1/2007
Retention
PERM
Document Relationships
8D Consent 2007 1001
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
If Ma, maximum moment at mid-height of wall due to service lateral and eccentric loads, <br />including P4 effects, exceed (~/3) M~~, AS shall be calculated by Equation (14-8): <br />~, ., - 3 ~ ~.r + <br />2 <br />MT - 3 M~~ <br />2 ~ n <br />M., - 3 M~~ <br />2 <br />- 3 0 ~r <br />(I4-8) <br />If Ma does not exceed (~/3) Mir, 45 shall be calculated by Equation (14-9): <br />Ma <br />(14-9) <br />~s= ~ ~cr <br />Mir <br />where: <br />SM~.,Z <br />~r - 48E~1.t <br />SMnI ~~ <br />48E~1 ~,. <br />Section 7-5-180: CONVENTIONAL LIGHT-FRAME CONSTRUCTION Section <br />2308.12.4 of the Code is added to read as follows: <br />2308.]2.4 Braced wall line sheathing. <br />Braced wall lines shall be braced by one of the types of sheathing prescribed by Table 2308.12.4 <br />as shown in Figure 2308.9.3. The sum of lengths of braced wall panels at each braced wall line <br />shall conform to Table 2308.12.4. Braced wall panels shall be distributed along the length of the <br />braced wall line and start at not more than 8 feet (2438 mm) from each end of the braced wall <br />line. Panel sheathing joints shall occur over studs or blocking. Sheathing shall be fastened to <br />studs, top and bottom plates and at panel edges occurring over blocking. Wall framing to which <br />sheathing used for bracing is applied shall be nominal 2 inch wide [actual P/z inch (38 mm)] or <br />larger members. <br />Cripple walls having a stud height exceeding l4 inches (356 mm) shall be considered a story for <br />the purpose of this section and shall be braced as required for braced wall lines in accordance <br />with Table 2308.12.4. Where interior braced wall lines occur without a continuous foundation <br />below, the length of parallel exterior cripple wall bracing shall be one and one-half times the <br />lengths required by Table 2308.12.4. Where the cripple wall sheathing type used is Type S-W <br />and this additional length of bracing cannot be provided, the capacity of Type S-W sheathing <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.