Laserfiche WebLink
Section 7-5-815: <br />DEFII~lITIONS. <br />Unreinforced Masonry Wall: Shall mean a masonry wall that relies on the tensile strength of <br />masonry units, mortar and grout in resisting design loads, and in which the area of the <br />reinforcement is less than 25 percent of the minimum ratio required by the building code for <br />reinforced masonry. <br />Cross Wall: Shall mean awood-framed wall sheathed with any of the materials described in <br />Table Al-D or AlE or other system as defined in Section Al 11.3.5. Crosswalls shall be spaced <br />no more than 40 feet on center measured perpendicular to the direction of consideration, and <br />shall be placed in each story of the building. Crosswalls shall extend the full story height <br />between diaphragms. <br />Section 7-5-820: NOTICE AND ORDER. Whenever the Building Official determines by <br />inspection that any building is constructed with unreinforced masonry walls, he shall initiate <br />proceedings to cause the eventual conformance of such building to the standards of this Article. <br />The Building Official shall issue a notice and order directed to the record owner of the building, <br />which notice and order shall contain: <br />(a) The street address and a legal description sufficient for identification of the <br />premises upon which the building is located. <br />(b) A statement that the Building Official has found the building to be constructed <br />with unreinforced masonry walls and, therefore, subject to the minimum seismic <br />standards set forth in this Article. The order shall specify the classification of the <br />building based upon its present use, utilizing the classification set forth in the <br />Uniform Building Code. <br />(c) A statement requiring the record owner to cause a structural analysis of the <br />building to be made by a civil or structural engineer or architect, licensed by the <br />State of California. <br />(d) A statement requiring the record owner to submit to the Building Official within <br />one year of the service of the notice and order, the results of the structural <br />analysis, which shall either: (1) demonstrate to the satisfaction of the Building <br />Official that the building meets the minimum requirements of this Article, or; (2) <br />shall include a structural analysis and plans for the proposed alterations of the <br />building necessary to comply with the minimum requirements of this Article, or; <br />(3) shall include plans for the demolition of the building. <br />(e) A statement advising that any person having any title or legal interest in the <br />building may appeal from the notice and order of the Building Official, in the <br />manner set forth in Section 7-5-1210 within sixty (60) days from the date of <br />service of the notice and order. <br />ORDINANCE NO. 2007-030 3 <br />