My WebLink
|
Help
|
About
|
Sign Out
Home
CitySLUSD Liaison Highlights 2007 1205 v1
CityHall
>
City Clerk
>
City Council
>
Committees
>
City & SLUSD Liaison Committee
>
CitySLUSD Liaison Highlights 2007 1205 v1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2007 1:23:31 PM
Creation date
12/14/2007 2:40:39 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Committee Highlights
Document Date (6)
12/5/2007
Retention
PERM
Document Relationships
_CC Agenda 2007 1217
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1217
CitySLUSD Liaison Highlights 2007 1205 v2
(Superseded by)
Path:
\City Clerk\City Council\Committees\City & SLUSD Liaison Committee
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Evaluation of Aquatic Facilities <br />City of San Leandro <br />San Leandro High School <br />produce sufficient velocity to impart a substantial circulatory movement to the pool <br />water. <br />Saw cut existing pool structure and install floor returns. <br />(Estimated Cost: $27,000.00) <br />Exhibit 24: Pool Surface Delamination <br />5. The San Leandro High School Pool area does not have domestic water connections <br />available as required by Title 24, chapter 31B: <br />3117E Hose Bibbs. Hose bibs shall be provided for each pool and located so that all <br />portions of the pool deck may be reached with a 75 foot length of hose attached to the <br />hose bib. Hose bibs shall be located so that they do not constitute a safety hazard and <br />shall be protected against backJlow. <br />Additional hose bibs should be added to the pool to meet the minimum standard as noted <br />above. These hose bibs can be added when the pool deck is being replaced, which will <br />provide easy access to run the domestic water piping to the appropriate locations. <br />(Estimated Cost $2,500.00) <br />6. The current flow rate of the pool water is at a rate that is somewhere between eight to ten <br />hours in violation of Title 24, Chapter 31B: <br />3124E Turnover Time. The recirculation and purification system shall have <br />sufficient capacity to provide a complete turnover ofpool water in: <br />v. One-half hour or less for a spa pool. <br />November 2001 Aquatic Design Group, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.