Building A. Please see Exhibit A -Site Plan (Sheet 1 of 3) which shows the existing parking and <br />circulation configuration. The existing front parking area contains 31 spaces, which includes 11 <br />compact spaces and 20 standard spaces. For comparison, see Exhibit C (Sheet 3 of 3), an <br />enlarged partial site plan that shows the proposed redesign of the parking and circulation plan at <br />the front of the property. The redesign increases the amount of parking spaces by 12 spaces; to a <br />total of 43 spaces which includes 39 compact spaces and four standard size parking stalls. (Note: <br />compact parking stalls are eight feet wide by 16 feet deep and standard size parking stalls are <br />nine feet wide by 18.5 feet deep). <br />In addition to the 12 spaces gained at the front of the property, an extra space would be gained <br />with restriping beneath Building A. The existing configuration contains 26 standard stalls and <br />four compacts, totaling 30 spaces. The space would be restriped to have 24 standard stalls and <br />seven compact stalls, 31 spaces, a net gain of one. <br />Laundry Facilities <br />The Condominium Conversion Ordinance (Section 5-2412 F.) requires that a laundry area shall <br />be provided for each unit, or, if common laundry areas are provide, such facilities shall consist of <br />not less than one automatic washer and dryer for each five units or fraction thereof. The required <br />number of washers and dryers for 96 units is 20 each. There are currently four washers and dryers <br />located in each building, for a total of eight each. <br />The applicant has stated that there is inadequate drainage and venting to place washers and dryers <br />in each of the units. There is not enough physical space, drainage or venting capacity to install 20 <br />washers and dryers required by the ordinance in the two existing laundry rooms, one in each <br />basement level of each apartment building. There is physical room to install a total of 12 washers <br />and 12.dryers 9 (six in each building). The applicant is requesting an exception to the laundry <br />facilities requirement for a reduced number of washers and dryers (eight less washers and dryers <br />than are required). <br />Usable Open Space <br />As part of the approved planned development, the project was approved with limited usable <br />outdoor space with the decks and patios being approximately 53 square feet to 65 square feet. <br />There are a few ground floor patios that range from 107 square feet to 146 square feet. The <br />redwood deck, a common area, at the rear of the property overlooking the San Leandro Creek <br />comprises approximately 1,485 square feet. <br />STAFF ANALYSIS <br />The proposed fencing and gate along the Haas Avenue frontage shown on Exhibit A should be <br />disregarded. The Engineering and Transportation Department and Planning Division do not <br />recommend a gate and fence at the front of the property. The gate would have the potential to <br />obstruct traffic on Haas Avenue by visitors and residents cueing to enter the property. In addition, <br />the gate would prevent the convenience of access to the visitor parking spaces. Required visitor <br />parking is 0.25 spaces per unit of the required number, thus the 96 unit complex is required 24 <br />visitor parking spaces. <br />Planning Commission Staff Report January 11, 2007 <br />Wnnrlciriw Anartme~ntc Wnrlr CPecinn ______.___ - . __ _ Pace ~ of 6 <br />