Laserfiche WebLink
• Plans - indicating locations and types of repair/rehabilitations; onsite improvements <br />to be protected or restored to pre-construction condition; City Standard Plans <br />• Technical Specifications - 3 sets; prepared in the City's standard format using MS <br />Word format <br />• Cost Estimate- estimated cost of construction broken down into standard bid items for <br />all elements shown on the plans <br />Phase 3 - 100% Design <br />• Development of all items listed in Phase 2 above, incorporating City comments from <br />70% review <br />Phase 4 -Final Design <br />• Plans - 1 set incorporating City comments from 100% review, provided on mylar of <br />vellum, wet stamped & signed plus 1 set in AutoCAD 2000 format on CD ; <br />• Technical Specifications plus bid item list - 1 set, incorporating City comments from <br />100% review provided as a hard copy plus 1 electronic copy in MS Word format <br />• Final Cost Estimate- estimated cost of construction broken down into standard bid <br />items for all elements shown on the plans <br />City Deliverables <br />• Copies of documentation allowing access onto each individual private property <br />• CCTV data of sewer inspections <br />• 70% review comment <br />• 100% review comments <br />Schedule <br />• Topographical Survey and conceptual <br />repair plan of locations 1 & 2 6 weeks <br />• City review period 2 weeks <br />• 70% Design Submittal 4 weeks <br />• City review period 2 weeks <br />• 100% Design Submittal 2 weeks <br />• City review period 1 week <br />• Final Design Submittal 1 week <br />Total 18 weeks <br />Sanitary Sewer Pipeline Replacements 2007-08 Dec 21, 2007 <br />Project No. 07-593-52-211 Page 17 of 19 <br />