My WebLink
|
Help
|
About
|
Sign Out
Home
Ord 2002-018
CityHall
>
City Clerk
>
City Council
>
Ordinances
>
2002
>
Ord 2002-018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2008 4:02:13 PM
Creation date
7/2/2008 4:02:12 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Ordinance
Document Date (6)
9/16/2002
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) Design Compression and Tension Values. Compression stresses for <br />unreinforced masonry having a minimum design shear value of 3 psi shall <br />not exceed 100 psi. Design tension values for unreinforced masonry shall <br />not be permitted. <br />(h) Five percent of the existing rod anchors utilized as all or part of the required wall <br />anchors shall be tested in pullout by an approved testing laboratory. The <br />minimum number tested shall be four per floor, with two tests at walls with joists <br />framing into the wall and two tests at walls with joists parallel to the wall. The <br />test apparatus shall be supported on the masonry wall at a minimum distance of <br />the wall thickness from the anchor tested. The rod anchor shall be given a preload <br />of 3001bs. prior to establishing a datum for recording elongation. The tension test <br />load reported shall be recorded at one-eighth inch relative movement of the <br />anchor and the adjacent masonry surface. Results of all tests shall be reported. <br />The report shall include the test results as related to the wall thickness and joist <br />orientation. The allowable resistance value of the existing anchors shall be 40 <br />percent of the average of those tested anchors having the same wall thickness and <br />joist orientation. <br />(i) Qualification tests for devices used for wall anchorage shall be tested with the <br />entire tension load carried on the enlarged head at the exterior face of the wall. <br />Bond on the part of the device between the enlarged head and the interior wall <br />face shall be eliminated for the qualification tests. The resistance value assigned <br />the device shall be 20 percent of the average of the ultimate loads. <br />Section 7-5-865: INFORMATION REQUIRED ON PLANS. <br />(a) General. In addition to the seismic analysis required elsewhere in this Article, the <br />licensed engineer responsible for the seismic analysis of the building shall <br />determine and record the information required by this section on the approved <br />plans. <br />(b) Construction Details. The following requirements with appropriate construction <br />details shall be made part of the approved plans: <br />(1) All unreinforced masonry walls shall be anchored at the roof level by <br />tension bolts through the wall as specified in Table 5 of this Article or by <br />approved equivalent at a maximum anchor spacing of six feet. All <br />unreinforced masonry walls shall be anchored at all floors with tension <br />bolts through the wall or by existing rod anchors at the maximum anchor <br />spacing of six feet. All existing rod anchors shall be secured to the joists <br />to develop the required forces. The Building Official may require testing <br />to verify the adequacy of the embedded ends of existing rod anchors. <br />Tests when required shall conform to Section 7-5-1155A(h). When access <br />11 <br />