My WebLink
|
Help
|
About
|
Sign Out
Home
Ord 2002-025
CityHall
>
City Clerk
>
City Council
>
Ordinances
>
2002
>
Ord 2002-025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2008 4:16:52 PM
Creation date
7/2/2008 4:07:30 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Ordinance
Document Date (6)
9/16/2002
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(b) Automatic sprinkler systems shall be installed and maintained in operable <br />condition as specified in this Article and NFPA Standard 13, in all buildings or <br />structures: <br />Of all occupancy classifications except R3 (single-family and duplex) of <br />type IIN, III - 1 hour, IIIN, IV, V - 1 hour or VN construction, the total <br />floor area of which exceeds 7,500 square feet, irrespective of area <br />separation walls. <br />2. Of all occupancy classifications, except R3 (single-family and duplex) of <br />type I or II -fire resistive construction, the total floor area of which <br />exceeds 10,000 square feet, irrespective of area separation walls. <br />Of all occupancy classifications, irrespective of construction type, the <br />overall height of which exceeds 45 feet. Building height shall be <br />determined in accordance with Section 209 of the Building Code. <br />(c) The provisions of this section shall apply to existing buildings or structures when, <br />over any three year period,: <br />1) Permits for additions and alterations increase the floor area by 25 percent. <br />2) Permit valuation for additions, alterations, repairs or other modifications, <br />individually or cumulatively, exceeds 25 percent of building valuation <br />determined by the building official. <br />(d) Automatic sprinkler systems installed within buildings shall have all control <br />valves and flow devices electrically supervised and maintained by an approved <br />Central Alarm Station, as defined in Section 1006.3.3.6.1. Buildings in existence <br />upon the effective date of this subsection shall be made to conform to the <br />provisions herein within one year from said effective date. <br />Section 3-3-265: RESERVED. <br />Section 3-3-270: RESERVED. <br />Section 3-3-275: RESERVED. <br />Section 3-3-280: RESERVED. <br />Section 3-3-285: RESERVED. <br />
The URL can be used to link to this page
Your browser does not support the video tag.