My WebLink
|
Help
|
About
|
Sign Out
Home
8E Consent 2010 1018
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1018
>
8E Consent 2010 1018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2010 5:11:34 PM
Creation date
10/14/2010 5:29:00 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date ā(6)ā
10/18/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1018
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1018
MO 2010-039
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2010
Reso 2010-131
(Reference)
Path:
\City Clerk\City Council\Resolutions\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
into opposite sides of the column, the moment components may be assumed to be of opposite <br /> sign. For the determination of the design strength. tpP,,, of the column, these moments may be <br /> assumed to result from the deformation of the frame in any one principal axis. <br /> 1908.1.13 AC1 318, Section 21.9.4. Modify ACI 318. Section 21.9.4, by adding Section 21.9.4.6 to <br /> read as follows: <br /> 21.9.4.6 ā Walls and portions of walls with Pā > 0.35P shall not be considered to contribute to the <br /> calculated strength of the structure for resisting earthquake- induced forces. Such walls shall conform <br /> to the requirements of ACI 318 Section 21.13. <br /> 1908.1.14 ACI 318, Section 21.11.6. Modify ACI 318, Section 21.1 1.6, by adding the following: <br /> Collector and boundary elements in topping slabs placed over precast floor and roof elements shall <br /> not be less than 3 inches (76 mm) or 6 db thick. where db is the diameter of the largest reinforcement <br /> in the topping slab. <br /> Section 7 -5 -190: CONVENTIONAL LIGHT -FRAME CONSTRUCTION <br /> Section 2301.2, method 3 of California Building Code, 2010 edition is revised as follows: <br /> Delete Exception. <br /> Section 4.3.4 of SDPWS 2008 Edition is amended as follows: <br /> Delete rows 5 & 6 and footnote 2 of Table 4.3.4 <br /> Section 2306.7 of the California Building Code, 2010 is amended as follows: The text of the <br /> exemption is not changed. <br /> 2306.7 Shear walls sheathed with other materials. Shear walls sheathed with Portland <br /> cement plaster, gypsum lath, gypsum sheathing or gypsum board shall be designed and <br /> constructed in accordance with AF &PA SDPWS. Shear walls sheathed with these materials <br /> are permitted to resist horizontal forces using the allowable shear capacities set forth in Table <br /> 2306.7. Shear walls sheathed with Portland cement plaster, gypsum lath, gypsum sheathing <br /> or gypsum board shall not be used to resist seismic forces in structures assigned to Seismic <br /> design Category D. E or F. <br /> Exception: [text unchanged] <br /> 5 <br />