Home
8E Consent 2010 1018
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1018
>
8E Consent 2010 1018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2010 5:11:34 PM
Creation date
10/14/2010 5:29:00 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
10/18/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1018
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1018
MO 2010-039
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2010
Reso 2010-131
(Reference)
Path:
\City Clerk\City Council\Resolutions\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
and one -half times the lengths required by Table 2308.12.4. Where the cripple wall sheathing <br /> type used is Type S -W and this additional length of bracing cannot be provided, the capacity <br /> of Type S -W sheathing shall be increased by reducing the spacing of fasteners along the <br /> perimeter of each piece of sheathing to 4 inches (102 mm) o.c. <br /> Table 2308.12.4 of the California Building Code 2010 Edition is amended as follows: <br /> TABLE 2308.12.4 <br /> WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E <br /> (Minimum Length of Wall Bracing per each 25 Linear Feet of Braced Wall Line <br /> CONDITION SHEATHING <0.50 0.50 < S <0.75 0.75 <S s1.00 Sns <br /> TYPEn S to n < > 1.00 <br /> One Story S -W 5 feet 8 feet 9 feet 12 feet <br /> 4 inches 0 inches 4 inches 0 inches <br /> For SI: 1 inch = 25.4 mm. 1 foot = 304.8 mm. <br /> Section 7 -5 -195: REPAIRS Section 3405 is amended as follows <br /> 3403.6.1 Repairs. Repairs of structural elements shall comply with this section. <br /> 3403.6.1.1 Seismic evaluation and design. Seismic evaluation and design of an existing <br /> building and its components shall be based on the following criteria. <br /> 3403.6.1.1.1 Evaluation and design procedures. The seismic evaluation and design shall be <br /> based on the procedures specified in the building code, ASCE 31 Seismic Evaluation of Existing <br /> Buildings (for evaluation only) or ASCE 41 Seismic Rehabilitation of Existing Buildings. The <br /> procedures contained in Appendix A of the International Existing Building Code shall be <br /> permitted to be used as specified in Section 3403.6.1.1.3. <br /> 3403.6.1.1.2 CRC level seismic forces. When seismic forces are required to meet the building <br /> code level, they shall be one of the following: <br /> 1. 100 percent of the values in the building code. The R factor used for analysis in <br /> accordance with Chapter 16 of the building code shall be the R factor specified for <br /> structural systems classified as "Ordinary" unless it can be demonstrated that the <br /> structural system satisfies the proportioning and detailing requirements for systems <br /> classified as "Intermediate" or "Special ". <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.