My WebLink
|
Help
|
About
|
Sign Out
Home
8E Consent 2010 1018
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1018
>
8E Consent 2010 1018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2010 5:11:34 PM
Creation date
10/14/2010 5:29:00 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
10/18/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1018
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1018
MO 2010-039
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2010
Reso 2010-131
(Reference)
Path:
\City Clerk\City Council\Resolutions\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have <br /> a total area of less than 0.002 times the gross cross sectional area of the footing. <br /> Sections 1908.1.11 through 1908.1.14 are added as follows: <br /> 1908.1.11 ACI 318, Section 21.6.4.1. Modify ACI 318, Section 21.6.4.1, to read as follows: <br /> Where the calculated point of contraflexure is not within the middle half of the member <br /> clear height, provide transverse reinforcement as specified in ACI 318 Sections 21.6.4.1. <br /> Items (a) through (c), over the full height of the member. <br /> 1908.1.12 ACI 318, Section 21.6.4. Modify ACI 318, Section 21.6.4, by adding Section 21.6.4.8 <br /> to read as follows: <br /> 21.6.4.8 — At any section where the design strength, cpP,,, of the column is Tess than the <br /> sum of the shears V computed in accordance with ACI 318 Sections 21.5.4.1 and <br /> 21.6.5.1 for all the beams framing into the column above the level under consideration, <br /> transverse reinforcement as specified in ACI 318 Sections 21.6.4.1 through 21.6.4.3 shall <br /> be provided. For beams framing into opposite sides of the column. the moment <br /> components may be assumed to be of opposite sign. For the determination of the design <br /> strength, cpP,,, of the column, these moments may be assumed to result from the <br /> deformation of the frame in any one principal axis. <br /> 1908.1.13 ACI 318, Section 21.9.4. Modify ACI 318. Section 21.9.4, by adding Section 21.9.4.6 <br /> to read as follows: <br /> 21.9.4.6 — Walls and portions of walls with P„ > 0.35P shall not be considered ' t o <br /> contribute to the calculated strength of the structure for resisting earthquake- induced <br /> forces. Such walls shall conform to the requirements of ACI 318 Section 21.13. <br /> 1908.1.14 ACI 318, Section 21.11.6. Modify ACI 318, Section 21.11.6. by adding the <br /> following: <br /> Collector and boundary elements in topping slabs placed over precast floor and roof <br /> elements shall not be less than 3 inches (76 mm) or 6 d thick, where d is the diameter of <br /> the largest reinforcement in the topping slab. <br /> Section 7 -5 -190: CONVENTIONAL LIGHT -FRAME CONSTRUCTION <br /> Section 2301.2, method 3 of California Building Code, 2010 edition is revised as follows: <br /> Delete Exception. <br /> Section 4.3.4 of SDPWS 2008 Edition is amended as follows: <br /> Delete rows 5 & 6 and footnote 2 of Table 4.3.4 <br /> Section 2306.7 of the California Building Code, 2010 is amended as follows: <br /> 26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.