My WebLink
|
Help
|
About
|
Sign Out
Home
3B Public Hearing 2010 1115
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1115
>
3B Public Hearing 2010 1115
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2010 9:36:14 AM
Creation date
11/10/2010 3:14:08 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
11/15/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1115
Ord 2010-013
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-014
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-015
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-016
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-017
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-018
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-019
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-020
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
area need not be considered as adjacent buildings for the provisions of this Chapter, provided <br />that the arcades are of not less than one (1) hour fire resistive construction or are constructed <br />entirely of noncombustible materials, fire retardant treated wood or heavy timber construction <br />with two -inch (2 ") nominal sheathing, or a combination of the above materials. <br />Section 7 -5 -135 EMERGENCY ESCAPE AND RESCUE OPENINGS <br />8310.1 Emergency escape and rescue required of the California Residential Code , 2010 <br />Edition is amended as follows: <br />Where emergency escape and rescue openings are provided they shall have the bottom of <br />the clear opening not greater than 44 inches (1,118 mm) measured from the floor." <br />Section 7 -5 -140 <br />Section 7 -5 -145 <br />RESERVED <br />MULTIPLE HAZARDS: OUTDOOR STORAGE <br />(a) When a hazardous material has multiple hazards, all hazards shall be addressed and <br />controlled in accordance with the provisions of this chapter. When overhead <br />noncombustible construction is provided for sheltering exterior hazardous material <br />storage areas, such storage shall not be considered indoor storage when all of the <br />following conditions are met: <br />(1) Supports shall be of noncombustible construction. <br />(2) Supports and walls shall not obstruct more than 25 percent of the perimeter <br />of the storage area. <br />(3) The distance to buildings, property lines, streets, alleys, public ways or exits <br />to a public way shall not be less than the distance required for an exterior <br />hazardous material storage area without weather protection. <br />Section 7 -5 -150 SIDEWALK ARCADES IN REDEVELOPMENT AREA In an <br />established Redevelopment Project Area, the Redevelopment Agency may approve the <br />installation of sidewalk arcades on public property. Except for vertical columns, such arcades <br />shall be not less than eight feet (8) above the pavement below. <br />Section 7 -5 -155 NONCOMBUSTIBLE CONSTRUCTION Section 414.6.1.3 of the Code <br />is added to read as follows: <br />414.6.1.3 Noncombustible construction. The overhead structure shall be of approved <br />noncombustible construction with a maximum area of 3,000 square feet (I 40M). <br />Section 7 -5 -160 MODIFICATIONS TO 2010 CBC AND ASCE 7 is added to read as <br />follows: <br />Section 1612.3 of the 2010 California Building Code is amended to read as follows. The text <br />of the exemption is not changed. <br />1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the <br />governing body shall adopt a flood hazard map and supporting data. The flood hazard <br />ORDINANCE NO. 2010-013 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.