My WebLink
|
Help
|
About
|
Sign Out
Home
3B Public Hearing 2010 1115
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1115
>
3B Public Hearing 2010 1115
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2010 9:36:14 AM
Creation date
11/10/2010 3:14:08 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
11/15/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1115
Ord 2010-013
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-014
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-015
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-016
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-017
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-018
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-019
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-020
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(b) Existing Materials <br />(1) Unreinforced Masonry Walls. Unreinforced masonry walls analyzed in <br />accordance with this Article may provide vertical support for roof and floor <br />construction and resistance to lateral loads. The facing and backing of such <br />walls shall be bonded so that not less than 4 percent of the exposed face area is <br />composed of solid headers extending not less than 4 inches into the backing. <br />The distance between adjacent full - length headers shall not exceed 24 inches <br />vertically or horizontally. Where the backing consists of two or more wythes <br />the header shall extend not less than 4 inches into the most distant wythe, or the <br />backing wythes shall be bonded together with separate headers whose area and <br />spacing conform to the foregoing. <br />Tension stresses due to seismic forces normal to the wall may be neglected if the <br />walls do not exceed the height to thickness ratio in Table 2 of this Article and <br />the in -plane shear stresses due to seismic loads as set forth in Table 3 of this <br />Article, and the in -plane shear stresses due to seismic loads as set forth in Table <br />4 of this Article. If the wall height - thickness ratio exceeds the specified limits, <br />the wall may be supported by vertical bracing members designed in accordance <br />with Section 7 -5 -855. The deflection of such bracing member at design loads <br />shall not exceed one -tenth of the wall thickness. <br />All vertical bracing members shall be attached to the floor and roof construction <br />for their design loads independently of required wall anchors. Horizontal <br />spacing of vertical bracing members shall not exceed one -half the unsupported <br />height of the wall nor ten feet. The wall height may be measured vertically to <br />bracing elements other than a floor or roof. Spacing of the bracing elements and <br />wall anchors shall not exceed six feet. Bracing elements shall be detailed to <br />minimize the horizontal displacement of the wall by components of vertical <br />displacements of the floor or roof. <br />(2) Existing Roof, Floors, Walls, Footings, and Wood Framing. Existing materials <br />including wood shear walls utilized in the described configuration may be used <br />as part of the lateral load resisting system, provided that the stresses in these <br />materials do not exceed the values shown in Table 4 of this Article. <br />(c) Strengthening of Existing Materials New materials including wood shear walls may <br />be utilized to strengthen portions of the existing seismic resisting system in the <br />described configurations provided that the stresses do not exceed the values shown in <br />Table 5 of this Article. <br />(d) Alternative Materials Alternative materials, designs and methods of construction <br />may be approved by the Building Official in accordance with the provisions of the <br />International Building Code. <br />ORDINANCE NO. 2010-018 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.