Laserfiche WebLink
area need not be considered as adjacent buildings for the provisions of this Chapter, provided <br /> that the arcades are of not Tess than one (1) hour fire resistive construction or are constructed <br /> entirely of noncombustible materials, fire retardant treated wood or heavy timber construction <br /> with two -inch (2 ") nominal sheathing, or a combination of the above materials. <br /> Section 7 -5 -135 EMERGENCY ESCAPE AND RESCUE OPENINGS <br /> R310.1 Emergency escape and rescue required of the California Residential Code , 2010 <br /> Edition is amended as follows: <br /> Where emergency escape and rescue openings are provided they shall have the bottom of <br /> the clear opening not greater than 44 inches (1,118 rum) measured from the floor." <br /> Section 7 -5 -140 RESERVED <br /> Section 7 -5 -145: MULTIPLE HAZARDS: OUTDOOR STORAGE. <br /> (a) When a hazardous material has multiple hazards, all hazards shall be addressed and <br /> controlled in accordance with the provisions of this chapter. When overhead <br /> noncombustible construction is provided for sheltering exterior hazardous material <br /> storage areas, such storage shall not be considered indoor storage when all of the <br /> following conditions are met: <br /> (1) Supports shall be of noncombustible construction. <br /> (2) Supports and walls shall not obstruct more than 25 percent of the perimeter <br /> of the storage area. <br /> (3) The distance to buildings, property lines, streets, alleys, public ways or exits <br /> to a public way shall not be less than the distance required for an exterior <br /> hazardous material storage area without weather protection. <br /> Section 7 -5 -150: SIDEWALK ARCADES IN REDEVELOPMENT AREA. In an <br /> established Redevelopment Project Area, the Redevelopment Agency may approve the <br /> installation of sidewalk arcades on public property. Except for vertical columns, such arcades <br /> shall be not Tess than eight feet (8') above the pavement below. <br /> Section 7 -5 -155: NONCOMBUSTIBLE CONSTRUCTION Section 414.6.1.3 of the Code <br /> is added to read as follows: <br /> 414.6.1.3 Noncombustible construction. The overhead structure shall be of approved <br /> noncombustible construction with a maximum area of 3,000 square feet (140m <br /> Section 7 -5 -160: MODIFICATIONS TO 2010 CBC AND ASCE 7 is added to read as <br /> follows: <br /> Section 1612.3 of the 2010 California Building Code is amended to read as follows. The text <br /> of the exemption is not changed. <br /> 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the <br /> governing body shall adopt a flood hazard map and supporting data. The flood hazard <br /> ORDINANCE NO. 2010 -013 22 <br />