22.10.1 - Structures assigned to Seismic Design Category C, D, E or F shall not have <br /> elements of structural plain concrete, except as follows: <br /> (a) Isolated footings of plain concrete supporting pedestals or columns are permitted, <br /> provided the projection of the footing beyond the face of the supported member does <br /> not exceed the footing thickness. <br /> Exception: In detached one and two - family dwelling three stories or less in height, <br /> the projection of the footing beyond the face of the supported member is permitted to <br /> exceed the footing thickness. <br /> (b) Plain concrete footing supporting walls are permitted, provided the footings have at <br /> least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. <br /> 4 and shall have a total area of not less than 0.002 times the gross cross - sectional area <br /> of the footing. A minimum of one bar shall be provided at the top and bottom of the <br /> footing. Continuity of reinforcement shall be provided at comers and intersections. <br /> Exception: In detached one and two - family dwellings three stores or less in height <br /> and constructed with stud bearing walls, plain concrete footings -with at least two <br /> continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have <br /> a total area of less than 0.002 times the gross cross sectional area of the footing. <br /> Sections 1908.1.11 through 1908.1.14 are added as follows: <br /> 1908.1.11 ACI 318, Section 21.6.4.1. Modify ACI 318, Section 21.6.4.1, to read as follows: <br /> Where the calculated point of contraflexure is not within the middle half of the member <br /> clear height, provide transverse reinforcement as specified in ACI 318 Sections 21.6.4.1, <br /> Items (a) through (c), over the full height of the member. <br /> 1908.1.12 ACI 318, Section 21.6.4. Modify ACI 318, Section 21.6.4, by adding Section 21.6.4.8 <br /> to read as follows: <br /> 21.6.4.8 — At any section where the design strength, 9P,,, of the column is less than the <br /> sum of the shears V computed in accordance with AC1 318 Sections 21.5.4.1 and <br /> 21.6.5.1 for all the beams framing into the column above the level under consideration, <br /> transverse reinforcement as specified in ACI 318 Sections 21.6.4.1 through 21.6.4.3 shall <br /> be provided. For beams framing into opposite sides of the column, the moment <br /> components may be assumed to be of opposite sign. For the determination of the design <br /> strength, tpP,,, of the column, these moments may be assumed to result from the <br /> deformation of the frame in any one principal axis. <br /> 1908.1.13 ACI 318, Section 21.9.4. Modify ACI 318, Section 21.9.4, by adding Section 21.9.4.6 <br /> to read as follows: <br /> ORDINANCE NO. 2010 -013 26 <br />