Home
Ord 2013-009
CityHall
>
City Clerk
>
City Council
>
Ordinances
>
2013
>
Ord 2013-009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2013 10:21:05 AM
Creation date
11/22/2013 10:17:02 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Ordinance
Retention
PERM
Document Relationships
4A Public Hearing 2013 1118
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2013\Packet 2013 1118
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
sum of the shears Ve computed in accordance with ACI 318 Sections 21.5.4.1 and <br />21.6.5.1 for all the beams framing into the column above the level under consideration, <br />transverse reinforcement as specified in ACI 318 Sections 21.6.4.1 through 21.6.4.3 shall <br />be provided. For beams framing into opposite sides of the column, the moment <br />components are permitted to be assumed to be of opposite sign. For the determination of <br />the design strength, ϕPn, of the column, these moments are permitted to be assumed to <br />result from the deformation of the frame in any one principal axis. <br /> <br />1905.1.11 ACI 318, Section 21.9.4. Modify ACI 318, Section 21.9.4, by adding Section <br />21.9.4.6 to read as follows: <br /> <br />21.9.4.6 – Walls and portions of walls with Pu > 0.35Po shall not be considered to <br />contribute to the calculated shear strength of the structure for resisting earthquake- <br />induced forces. Such walls shall conform to the requirements of ACI 318 Section 21.13. <br /> <br />1905.1.12 ACI 318, Section 21.11.6. Modify ACI 318, Section 21.11.6.1, as follows: <br /> <br />21.11.6.1 Collector and boundary elements in topping slabs placed over precast floor and <br />roof elements shall not be less than 3 inches (76 mm) or 6 db in thickness, where db is the <br />diameter of the largest reinforcement in the topping slab. <br /> <br />Section 7-5-190: CONVENTIONAL LIGHT-FRAME CONSTRUCTION <br /> <br />Section 2301.2, method 3 of California Building Code, 2013 edition is revised as follows: <br /> <br />Delete Exception. <br /> <br />Section 4.3.4 of SDPWS 2008 Edition is amended as follows: <br /> <br />Delete rows 5 & 6 and footnote 2 of Table 4.3.4 <br /> <br />Section 2306.3 of the California Building Code, 2013 is amended as follows: <br /> <br />Section 2306.3 Wood –frame shear walls. Wood –frame shear walls shall be designed <br />and constructed in accordance with AF&PA SDPWS. Where panels are fastened to <br />framing members with staples, requirements and limitations of AF&PA SDPWS shall be <br />met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) <br />shall be permitted. The allowable shear values in Tables 2306.3(1) and 2306.3(2) are <br />permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA <br />PRP-210 shall be permitted to use design values for Plywood Siding in the AF&PA <br />SDPWS. Shear walls sheathed with Portland cement plaster, gypsum lath, gypsum <br />sheathing or gypsum board shall not be used to resist seismic forces in structures <br />assigned to Seismic design Category D, E or F. <br /> <br />Section 2308.1 of the California Building Code, 2013 Edition is amended as follows: <br />