My WebLink
|
Help
|
About
|
Sign Out
Home
Ord 2013-017
CityHall
>
City Clerk
>
City Council
>
Ordinances
>
2013
>
Ord 2013-017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2013 10:17:05 AM
Creation date
11/22/2013 10:17:04 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Ordinance
Retention
PERM
Document Relationships
4A Public Hearing 2013 1118
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2013\Packet 2013 1118
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sections 102.0 - 102.3.2 of the Uniform Plumbing Code are hereby deleted. Enforcement and <br /> abatement procedures set forth in the San Leandro Building Code or Articles 11, 12, and 13 of <br /> this Chapter shall apply to this Article. <br /> Section 7-5-915: MATERIALS. <br /> A. Section 316.3.1 of the Uniform Plumbing Code is hereby deleted and replaced to read as <br /> follows: <br /> Fixture connections between drainage pipes and water closets, floor outlet service sinks and <br /> urinals shall be made by means of approved brass, hard lead, or iron flanges caulked or soldered; <br /> rubber compression gaskets; or screwed to the drainage pipe. The connection shall be bolted with <br /> an approved gasket, washer, or setting compound between the fixture and connection. The <br /> bottom of the flange shall be set on an approved firm base. <br /> B. Sections 408.4.1 and 408.4.3 of the Uniform Plumbing Code is hereby deleted and replaced <br /> to read as follows: <br /> Section 408.4.1 - Closet rings (closet flanges) for water closets or similar fixtures shall be of an <br /> approved type and shall be bronze, copper, hard lead, cast iron, galvanized malleable iron, or <br /> other approved materials. Each such closet ring (closet flange) shall be approximately seven (7) <br /> inches (175 mm) in diameter and, when installed, shall, together with the soil pipe, present a one <br /> and one-half(l-1/2) inch (38 mm) wide flange or face to receive the fixture gasket or closet seal. <br /> Section 408.4.3 - Closet rings (closet flanges) shall be burned or soldered to lead bends or stubs, <br /> shall be caulked to cast-iron soil pipe, and shall be screwed or fastened in an approved manner <br /> to other materials. <br /> C. Section 701.1.2 of the Uniform Plumbing Code - Materials for Drainage Piping - is hereby <br /> deleted and replaced to read as follows: <br /> ABS and PVC drainage piping installations are not allowed. <br /> D. Section 701.2 - Materials of the Uniform Plumbing Code - is hereby deleted and replaced to <br /> read as follows: <br /> Materials for drainage fittings shall be in accordance with the applicable standards referenced in <br /> Table 7-1 of the same diameter as the piping served, except that ABS and PVC installations are <br /> not allowed, and such fittings shall be compatible with the type of pipe used. <br /> E. Section 903.1.2 - Materials of the Uniform Plumbing Code - is hereby deleted and replaced <br /> to read as follows: <br /> ABS and PVC vent piping and fittings are not allowed. <br /> ORDINANCE NO. 2013-017 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.