My WebLink
|
Help
|
About
|
Sign Out
Home
4A Public Hearing 2016 0516
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2016
>
Packet 2016 0516
>
4A Public Hearing 2016 0516
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 9:04:41 AM
Creation date
5/11/2016 5:29:31 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
5/16/2016
Retention
PERM
Document Relationships
_CC Agenda 2016 0516 CS+RG
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2016\Packet 2016 0516
Reso 2016-054
(Reference)
Path:
\City Clerk\City Council\Resolutions\2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
BACnet Communication Option Points List for 27T <br />Project: Climatec Energy - City of San Leandro 01/15/2016 <br />Prepared By: 02:54PM <br />AV:179 <br />User Determined OAQ <br />W <br />n/a <br />400 <br />0-5000 <br />oa user 1 <br />OAQ USER <br />AV:180 <br />VAV Occ. Cool Off Delta <br />W <br />-AF <br />2 <br />1-25 <br />vavocoff1 <br />VAVOCOFF <br />AV:181 <br />VAV Occ. Cool On Delta <br />W <br />-AF <br />3.5 <br />0-25 <br />vavocon 1 <br />VAVOCON <br />AV:182 <br />VAV Unocc Fan Retry Time <br />W <br />min <br />60 <br />0-720 <br />sam mins 1 <br />SAMPMINS <br />AV:183 <br />Vent Reheat RAT Offset <br />W <br />-AF <br />0 <br />0-8 <br />dhvraoff 1 <br />DHVRAOFF <br />AV:184 <br />Vent Reheat Setpoint <br />W <br />psig <br />70 <br />55-95 <br />dhvht s 1 <br />DHVHT SP <br />AV:185 <br />Vent Reheat Setpt Select <br />W <br />0 <br />0-1 <br />dhvhtcf 1 <br />DHVHTCFG <br />AV:186 <br />VFD/Act. Fire Speed/Pos. <br />W <br />IF <br />100 <br />0-100 <br />bldgpfso_1 <br />BLDGPFSO <br />AV:187 <br />VFD Fire Speed Override <br />W <br />100 <br />0-100 <br />statpfso_1 <br />STATPFSO <br />AV:188 <br />VFD Maximum Speed <br />W <br />% <br />100 <br />0-100 <br />stat max 1 <br />STATPMAX <br />AV:189 <br />VFD Minimum Speed <br />W <br />% <br />20 <br />0-100 <br />statpmin_1 <br />STATPMIN <br />AV:1003 <br />Outside Air Temperature <br />W <br />-F <br />n/a <br />-40-240 <br />oat 1 <br />OAT <br />AV:1009 <br />IAQ - PPM Indoor CO2 <br />W <br />n/a <br />n/a <br />0-5000 <br />aa 1 <br />IAQ <br />AV:1016 <br />Static Pressure <br />R <br />in H2O <br />n/a <br />n/a <br />static_press_1 <br />SP <br />AV:1022 <br />HVAC Mode Numerical Form <br />R <br />n/a <br />n/a <br />n/a <br />hvac mode 1 <br />MODEHVAC <br />AV:1023 <br />Current Running Capacity <br />R <br />% <br />n/a <br />n/a <br />cool ca acit 1 <br />CAPTOTAL <br />AV:1024 <br />Cooling Control Point <br />R <br />-F <br />n/a <br />n/a <br />cool_ctrl_point_1 <br />COOLCPNT <br />AV:1025 <br />Heating Control Point <br />R <br />-F <br />n/a <br />n/a <br />heat ctrl oint 1 <br />HEATCPNT <br />AV:1027 <br />Leaving Air Temperature <br />R <br />°F <br />n/a <br />n/a <br />Ivg_air_temperature_1 <br />LAT <br />BACNET <br />OBJECTID <br />POINT NAME <br />READ <br />ONLY <br />UNITS <br />DEFAULT <br />VALUE <br />RANGE <br />BACNET <br />OBJECTNAME <br />UNIT <br />POINT <br />AV:1028 <br />Economizer Act. Curr. Pos <br />R <br />% <br />n/a <br />n/a <br />econ os 1 <br />ECONOPOS <br />AVA030 <br />Controlling Return Temp <br />W <br />-F <br />n/a <br />-40-240 <br />ra temp-1 <br />RETURN T <br />AV:1070 <br />Building Pressure <br />R <br />in H2O <br />n/a <br />n/a <br />bldg_static_press_1 <br />BP <br />AV:1500 <br />Mixed Air Temperature <br />R <br />°F <br />n/a <br />n/a <br />ma tem 1 <br />MAT <br />AV:1600 <br />Cir A Suction Pressure <br />R <br />psig <br />n/a <br />n/a <br />suction_press_a_1 <br />SP A <br />AV:1601 <br />Cir A Discharge Pressure <br />R <br />psig <br />n/a <br />n/a <br />discharge_press_a_1 <br />DP A <br />AV:1602 <br />Cir A Sat. Condensing Temperature <br />R <br />-F <br />n/a <br />n/a <br />sat Gond tem a 1 <br />SCTA <br />AV:1603 <br />Cir A Sat. Suction Temperature <br />R <br />-F <br />n/a <br />n/a <br />sat suction tem a 1 <br />SSTA <br />AV:1604 <br />Cir B Suction Pressure <br />R <br />psig <br />n/a <br />n/a <br />suction_press_b_1 <br />SP B <br />AV:1605 <br />Cir B Discharge Pressure <br />R <br />psig <br />n/a <br />n/a <br />discharge—press b 1 <br />DP B <br />AV:1606 <br />Cir B Sat. Condensing Temperature <br />R <br />°F <br />n/a <br />n/a <br />sat_cond_temp_b_1 <br />SCTB <br />AV:1607 <br />Cir B Sat. Suction Temperature <br />R <br />-F <br />n/a <br />n/a <br />sat suction temp_b_1 <br />SSTB <br />AV:2003 <br />Requested Heat Stage <br />R <br />n/a <br />n/a <br />n/a <br />heat run 1 <br />HT STAGE <br />AV:2007 <br />Controlling Space Temp <br />W <br />-F <br />n/a <br />-40-240 <br />s ace tem 1 <br />SPACE T <br />AV:2050 <br />Supply Fan VFD Speed <br />R <br />% <br />n/a <br />n/a <br />sfvfdtst 1 <br />SFAN VFD <br />AV:2075 <br />Exhaust Fan VFD Speed <br />R <br />% <br />n/a <br />n/a <br />of vfd out ut 1 <br />EFAN VFD <br />AV:2901 <br />User Defined Analog 1 <br />n/a <br />n/a <br />n/a <br />n/a <br />user analog_1_1 <br />n/a <br />AV:2902 <br />User Defined Analog 2 <br />n/a <br />n/a <br />n/a <br />n/a <br />user analog_2_1 <br />n/a <br />AV:2903 <br />User Defined Analog 3 <br />n/a <br />n/a <br />n/a <br />n/a <br />user analog -3 1 <br />n/a <br />AV:2904 <br />User Defined Analog 4 <br />n/a <br />n/a <br />n/a <br />n/a <br />user analog_4_1 <br />n/a <br />AV:2905 <br />User Defined Analog 5 <br />n/a <br />n/a <br />n/a <br />n/a <br />user analog_5_1 <br />1 n/a <br />Applied Rooftop Builder 3.19m Page 13 of 48 <br />
The URL can be used to link to this page