My WebLink
|
Help
|
About
|
Sign Out
Home
4A Public Hearing 2016 0516
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2016
>
Packet 2016 0516
>
4A Public Hearing 2016 0516
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 9:04:41 AM
Creation date
5/11/2016 5:29:31 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
5/16/2016
Retention
PERM
Document Relationships
_CC Agenda 2016 0516 CS+RG
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2016\Packet 2016 0516
Reso 2016-054
(Reference)
Path:
\City Clerk\City Council\Resolutions\2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Operational Savings <br />The Purchaser will realize maintenance and operational savings resulting from the new system installations, <br />extended warranties, and/or service agreements provided by Climatec LLC. The operational savings are agreed to <br />be met upon the completed installation of the energy retrofit contract. <br />Pre Retrofit Measurements <br />Existing operating hours and cooling/heating temperature setpoints for each HVAC unit or area will be obtained <br />from current thermostats/EMS. <br />Post Retrofit Measurements <br />Post -retrofit operating schedules, cooling and heating temperature setpoints in both occupied and unoccupied modes <br />for the HVAC equipment will be obtained using the new controls system. <br />Adjustments <br />For this FEM the following adjustments are allowed for purposes of Measurement and Verification: <br />➢ Addition or subtraction to the conditioned square footage of facilities. <br />➢ Utility rates, billing days or degree days. <br />➢ Equipment changes. <br />➢ Increase or decrease in facility usage as associated with daily occupancy times and special events. <br />Commissioning <br />Commissioning shall consist of inspections, and a final Commissioning report. The Inspections and Report shall <br />consist of: <br />➢ Commissioning of the energy management system (EMS) shall include verification that the operating <br />schedules, cooling and heating temperature set points and the control sequences for the HVAC equipment <br />have been programmed as specified. <br />Attachment A <br />*CLIMATEC� Page 13 of 13 <br />MERGING BUIL-DINGS & TECHNOLOGY <br />
The URL can be used to link to this page
Your browser does not support the video tag.