Specifications
<br />Model FS100B & FS150B Flow Sensor
<br />The flow sensor shall bean in line type with a nonmag-
<br />netic spinning impeller (paddle wheel) as the only mov-
<br />ing part. The electronics housing shall be glass -filled PPS.
<br />The impellershall be glass -filled nylon orTefzel®with
<br />a UHMWPE orTefzel sleeve bearing. The shaft material
<br />shall be tungsten carbide.The electronics housing shall
<br />have two, ethylenepropylene 0 -Rings and shall be easily
<br />removed from the meter body.The sensor electronics
<br />will be potted in an epoxycompound designed for
<br />prolonged immersion. Electrical connections shall be 2
<br />single conductor 18 AWG leads 48 inches (L2 meters)
<br />long. Insulation shall be direct burial"UF'type colored
<br />red for the positive lead and blackfor the negative lead.
<br />The sensor shall be capable of operating in line pres-
<br />sures up to 400 psi (27,5 bars) and liquid temperatures
<br />up to 220' F (105'C), and operating in flows of 112 foot
<br />(0,15 meters) per second to 15 feet (4,5 meters) per sec-
<br />ond with linearity oftl%and repeatability of±1%.The
<br />meter body shall be cast 85-5-5-5 bronze, in 1"(25 mm)
<br />and 11/2"(40 mm), female iron pipe thread sizes. This
<br />flow sensor shall be Rain Bird Model FS100B or `S1 50B.
<br />Model FS200B Flow Sensor
<br />The flow sensor shall be an insertion type with a
<br />nonmagnetic, spinning impeller (paddle wheel) as the
<br />only moving part The sensor sleeve shat l be bronze,
<br />with the sensor housing being PPS. The sensor shall be
<br />mounted in a 2"malleable bronze tee. The sensor shall
<br />be a nonmagnetic spinning impeller (paddle wheel) as
<br />the only moving part. The impeller shall be glass -filled
<br />nylon with a UHMWPE sleeve bearing. The shaft material
<br />shall be tungsten carbide. The sensor electronics will be
<br />potted in an epoxy compound designed for prolonged
<br />immersion, Electrical connections shall be 2single con-
<br />ductor 18 AWG leads 48 inches long, UL Style type PTLC
<br />wire. The sensor shall operate in line pressures up to 200
<br />psi and liquid temperatures up to 1 00' F, and operate in
<br />flows oft/2 foot per second to 30 feet per second with
<br />accuracy oft 1%of full scale and repeatability oft 03%.
<br />This flow sensor shall be Rain Bird Model FS200B,
<br />Model FS100P Flow Sensor
<br />The flow sensor shall bean in line type with a nonmag-
<br />netic spinning impeller(paddlewheel) as the only
<br />moving part.The impeller shall be made of 300SSTwith
<br />a UHMWPE sleeve bearing. The shaft material shall be
<br />tungsten carbide, The electronics housing shall be made
<br />of PPS. The electronics housing shall have two EPDM
<br />O -Rings and shall be easily removed tom the meter
<br />body. The sensor electronics will be potted in an epoxy
<br />compound designed for prolonged immersion with
<br />Rain Bird Corporation
<br />6991 E. Southpoint Road
<br />Tucson, AZ 85756
<br />Phone: (520) 741-6100
<br />Fax: (520) 741-6522
<br />Rain Bird Technical Services
<br />(800) RAINBIRD(1-800724-6247)
<br />(U.S. and Canada)
<br />Registered Trademark of Rain Bird Corporation
<br />9 2015 Rain Bird Corporation 8115
<br />RAIW*BIRD.
<br />2-conductor,18AWG solid copper wire leads extending
<br />from the top of the sensor, The sensor shall operate in
<br />line pressures up to 150 psi at liquid temperatures up
<br />to 73'F, or up to 75 PSIG at liquid temperatures up to
<br />110' FThe sensor shall operate in flows oft foot per
<br />second to 20 feet per second with linearityoft 31/. and
<br />repeatability oft 1.5%. The flow sensor shall generate a
<br />frequency which is proportional to flow rate. The meter
<br />body shall be fabricated from Schedule 40 PVCTees,
<br />Type 1, white, available in 1/2", 3/a'; and 1'(12mm, 20mm,
<br />and 25mm) solvent weld socket end connections.This
<br />flow sensor shall be Rain Bird Model FS 100P.
<br />Model FS1SOP, FS200P,FS300PorFS400P
<br />Flow Sensor
<br />The flow sensor shall be an in-line type with a non-
<br />magnetic spinning impeller (paddle wheel) as the only
<br />moving part The electronics housing shall be glass -filled
<br />PPS.The impeller shall be glass -filled nylon orTefzel with
<br />a UHMWPE orTefzel sleeve bearing.The shaft material
<br />shall be tungsten carbide. The electronics housing sha II
<br />have two, ethylenepropylene O -Rings and shall be easily
<br />removed from the meter body. The sensor electronics
<br />will be potted in an epoxy compound designed for pro-
<br />longs immersion. Electrical connections shall be 2 single
<br />conductor 18 AWG leads 48 inches (1,2 meters) long.
<br />Insulation shall be direct burial"UF"type colored red for
<br />the positive lead and black for the negative lead. The
<br />sensorshall be capable of operating in line pressure up
<br />to 100 psi (6.9 bars) and liquid temperatures up to 140'
<br />F (60'C), and operating in flows of W foot (Q15 meters)
<br />per second to 30 feet (9,2 meters) per second with li n-
<br />earityoft1%and repeatability oftl%The meter body
<br />shall be fabricated from Schedule 80 PVCTees, available
<br />in 1172, 2, 3, and 4"(40mm, 50mm, 75mm, and 110mm)
<br />with socket end connections. This flow sensor shall be
<br />Rain Bird Model FS 150P, FS200P, FS300P or F5400P.
<br />Model FS350B & FS350SS Flow Sensors
<br />The flow sensor shall be an insertion type with a
<br />nonmagneti4 spinning impeller (paddle wheel) as the
<br />only moving part. The sensor sleeve will be brass (or
<br />316 stainless steel) with the sensor housing being PPS.
<br />The impeller shall be glassfilled nylon orTeIzel with a
<br />UHMPWE orTefzel sleeve. The shaft material shall be
<br />tungsten carbide. The sensor will be supplied with a
<br />2"(50mm) NPT adapter for installation into any com-
<br />merdally availableweldon fitting or pipe saddle. The
<br />adapter shall have two, ethylenepropylene 0 -Rings. The
<br />sensor electronics will be potted in an epoxy compound
<br />designed for prolonged immersion. Electrical connec-
<br />tions shall be 2 single conductor 18AWG leads 48 inches
<br />(1,2 meters) long. Insulation shall be direct burial'UF'
<br />Rain Bird Corporation
<br />970 West Sierra Madre Avenue
<br />Azusa, CA 91702
<br />Phone: (626) 812-3400
<br />Fax: (626) 812-3411
<br />Specification Hotline
<br />800-458-3005 (U.S. and Canada)
<br />type colored red for the positive lead and black for the
<br />negative lead. Insertion of the sensor into any pipe size
<br />shall be 12'(40mm) from the insidewall to the end of
<br />the sensor housing.The sensor shall shall be capable of
<br />operating in line pressures up to400 psi (27,5 bars) and
<br />liquid temperatures up to 220'F (107C), and operating
<br />in flows of 1/2 foot (Q 15 meters) per second to 30 feet
<br />(9,2 meters) per second. This flow sensor shall be Rain
<br />Bird Model FS350B (FS350SS).
<br />Model PT322 Pulse Output Transmitter
<br />The Pulse Output Transmitter shall receive signals for any
<br />Rain Bird flow sensor and produce a dry contract closure
<br />in units of measure that can be defined by the user.
<br />Calibration shall be achieved by connecting to com-
<br />puter with Rain Bird PT322SWsoftware. All information
<br />set in the software is sent to the PT322 via a supplied
<br />cable.The PT322shall feature two diagnostic LED's, one
<br />corresponding to the input signal and one correspond-
<br />ing to the output signal. Model PT322 transmitter shall
<br />operate on 12-30VDCNAC power (using PTPWRSUPP
<br />Power Supply.) Models shall be provided in epoxy filled
<br />enclosures. The Pulse Output Transmitter shall be Rain
<br />Bird Model PT322.
<br />Model PT3002 Pulse Transmitter/FlowMonitor
<br />The flow monitor shall be a microprocessor based digital
<br />unit capable of calculating and displaying both rate of
<br />flow and total flow on a two line by sixteen character
<br />alpha -numeric LCD. The flow monitor shall accept digital
<br />inputs or optional sine wave or analog signal and may
<br />be field configured to display rate and total values in
<br />any unit of measure. NI data shall be entered via five
<br />keys mounted on the front panel.The monitor shall
<br />feature a software lock to protea the entered data from
<br />unauthorized changes. A nonvolatile memory, requiring
<br />no battery backupshall protect the data from electronic
<br />losses. The Model PT3002 shall conform to DIN standard
<br />dimensions for panel mounting, and shall feature a
<br />NEMA 4X rated front panel, in an optional NEMA 4 wall
<br />mount cabinet (NFMACAB). Monitor shall operate on
<br />power of 12-24 VAC/VDC (using PTPW RSUPP Power
<br />Supply.)The flow monitor shall feature standard open
<br />collector transistor outputs, one based on rate and one
<br />based on total. Setpoints or time delays for rate, scaling
<br />or pulse width for total may be configured in the field.
<br />Options shall include analog inputs, analog output or
<br />control relays, all programmable from the keypad. The
<br />flow monitor shall be Rain Bird Model PT3002.
<br />Tefzei' is a registered tradernarkof DuPont
<br />Rain Bird International, Inc.
<br />1000 West Sierra Madre Ave.
<br />Azusa, CA 91702
<br />Phone: (626) 963-9311
<br />Fax: (626) 852-7343
<br />The Intelligent Use ofWateC'
<br />www.rainbird.com
<br />D40785EO
<br />
|