Specifications <br />Model FS100B & FS150B Flow Sensor <br />The flow sensor shall bean in line type with a nonmag- <br />netic spinning impeller (paddle wheel) as the only mov- <br />ing part. The electronics housing shall be glass -filled PPS. <br />The impellershall be glass -filled nylon orTefzel®with <br />a UHMWPE orTefzel sleeve bearing. The shaft material <br />shall be tungsten carbide.The electronics housing shall <br />have two, ethylenepropylene 0 -Rings and shall be easily <br />removed from the meter body.The sensor electronics <br />will be potted in an epoxycompound designed for <br />prolonged immersion. Electrical connections shall be 2 <br />single conductor 18 AWG leads 48 inches (L2 meters) <br />long. Insulation shall be direct burial"UF'type colored <br />red for the positive lead and blackfor the negative lead. <br />The sensor shall be capable of operating in line pres- <br />sures up to 400 psi (27,5 bars) and liquid temperatures <br />up to 220' F (105'C), and operating in flows of 112 foot <br />(0,15 meters) per second to 15 feet (4,5 meters) per sec- <br />ond with linearity oftl%and repeatability of±1%.The <br />meter body shall be cast 85-5-5-5 bronze, in 1"(25 mm) <br />and 11/2"(40 mm), female iron pipe thread sizes. This <br />flow sensor shall be Rain Bird Model FS100B or `S1 50B. <br />Model FS200B Flow Sensor <br />The flow sensor shall be an insertion type with a <br />nonmagnetic, spinning impeller (paddle wheel) as the <br />only moving part The sensor sleeve shat l be bronze, <br />with the sensor housing being PPS. The sensor shall be <br />mounted in a 2"malleable bronze tee. The sensor shall <br />be a nonmagnetic spinning impeller (paddle wheel) as <br />the only moving part. The impeller shall be glass -filled <br />nylon with a UHMWPE sleeve bearing. The shaft material <br />shall be tungsten carbide. The sensor electronics will be <br />potted in an epoxy compound designed for prolonged <br />immersion, Electrical connections shall be 2single con- <br />ductor 18 AWG leads 48 inches long, UL Style type PTLC <br />wire. The sensor shall operate in line pressures up to 200 <br />psi and liquid temperatures up to 1 00' F, and operate in <br />flows oft/2 foot per second to 30 feet per second with <br />accuracy oft 1%of full scale and repeatability oft 03%. <br />This flow sensor shall be Rain Bird Model FS200B, <br />Model FS100P Flow Sensor <br />The flow sensor shall bean in line type with a nonmag- <br />netic spinning impeller(paddlewheel) as the only <br />moving part.The impeller shall be made of 300SSTwith <br />a UHMWPE sleeve bearing. The shaft material shall be <br />tungsten carbide, The electronics housing shall be made <br />of PPS. The electronics housing shall have two EPDM <br />O -Rings and shall be easily removed tom the meter <br />body. The sensor electronics will be potted in an epoxy <br />compound designed for prolonged immersion with <br />Rain Bird Corporation <br />6991 E. Southpoint Road <br />Tucson, AZ 85756 <br />Phone: (520) 741-6100 <br />Fax: (520) 741-6522 <br />Rain Bird Technical Services <br />(800) RAINBIRD(1-800724-6247) <br />(U.S. and Canada) <br />Registered Trademark of Rain Bird Corporation <br />9 2015 Rain Bird Corporation 8115 <br />RAIW*BIRD. <br />2-conductor,18AWG solid copper wire leads extending <br />from the top of the sensor, The sensor shall operate in <br />line pressures up to 150 psi at liquid temperatures up <br />to 73'F, or up to 75 PSIG at liquid temperatures up to <br />110' FThe sensor shall operate in flows oft foot per <br />second to 20 feet per second with linearityoft 31/. and <br />repeatability oft 1.5%. The flow sensor shall generate a <br />frequency which is proportional to flow rate. The meter <br />body shall be fabricated from Schedule 40 PVCTees, <br />Type 1, white, available in 1/2", 3/a'; and 1'(12mm, 20mm, <br />and 25mm) solvent weld socket end connections.This <br />flow sensor shall be Rain Bird Model FS 100P. <br />Model FS1SOP, FS200P,FS300PorFS400P <br />Flow Sensor <br />The flow sensor shall be an in-line type with a non- <br />magnetic spinning impeller (paddle wheel) as the only <br />moving part The electronics housing shall be glass -filled <br />PPS.The impeller shall be glass -filled nylon orTefzel with <br />a UHMWPE orTefzel sleeve bearing.The shaft material <br />shall be tungsten carbide. The electronics housing sha II <br />have two, ethylenepropylene O -Rings and shall be easily <br />removed from the meter body. The sensor electronics <br />will be potted in an epoxy compound designed for pro- <br />longs immersion. Electrical connections shall be 2 single <br />conductor 18 AWG leads 48 inches (1,2 meters) long. <br />Insulation shall be direct burial"UF"type colored red for <br />the positive lead and black for the negative lead. The <br />sensorshall be capable of operating in line pressure up <br />to 100 psi (6.9 bars) and liquid temperatures up to 140' <br />F (60'C), and operating in flows of W foot (Q15 meters) <br />per second to 30 feet (9,2 meters) per second with li n- <br />earityoft1%and repeatability oftl%The meter body <br />shall be fabricated from Schedule 80 PVCTees, available <br />in 1172, 2, 3, and 4"(40mm, 50mm, 75mm, and 110mm) <br />with socket end connections. This flow sensor shall be <br />Rain Bird Model FS 150P, FS200P, FS300P or F5400P. <br />Model FS350B & FS350SS Flow Sensors <br />The flow sensor shall be an insertion type with a <br />nonmagneti4 spinning impeller (paddle wheel) as the <br />only moving part. The sensor sleeve will be brass (or <br />316 stainless steel) with the sensor housing being PPS. <br />The impeller shall be glassfilled nylon orTeIzel with a <br />UHMPWE orTefzel sleeve. The shaft material shall be <br />tungsten carbide. The sensor will be supplied with a <br />2"(50mm) NPT adapter for installation into any com- <br />merdally availableweldon fitting or pipe saddle. The <br />adapter shall have two, ethylenepropylene 0 -Rings. The <br />sensor electronics will be potted in an epoxy compound <br />designed for prolonged immersion. Electrical connec- <br />tions shall be 2 single conductor 18AWG leads 48 inches <br />(1,2 meters) long. Insulation shall be direct burial'UF' <br />Rain Bird Corporation <br />970 West Sierra Madre Avenue <br />Azusa, CA 91702 <br />Phone: (626) 812-3400 <br />Fax: (626) 812-3411 <br />Specification Hotline <br />800-458-3005 (U.S. and Canada) <br />type colored red for the positive lead and black for the <br />negative lead. Insertion of the sensor into any pipe size <br />shall be 12'(40mm) from the insidewall to the end of <br />the sensor housing.The sensor shall shall be capable of <br />operating in line pressures up to400 psi (27,5 bars) and <br />liquid temperatures up to 220'F (107C), and operating <br />in flows of 1/2 foot (Q 15 meters) per second to 30 feet <br />(9,2 meters) per second. This flow sensor shall be Rain <br />Bird Model FS350B (FS350SS). <br />Model PT322 Pulse Output Transmitter <br />The Pulse Output Transmitter shall receive signals for any <br />Rain Bird flow sensor and produce a dry contract closure <br />in units of measure that can be defined by the user. <br />Calibration shall be achieved by connecting to com- <br />puter with Rain Bird PT322SWsoftware. All information <br />set in the software is sent to the PT322 via a supplied <br />cable.The PT322shall feature two diagnostic LED's, one <br />corresponding to the input signal and one correspond- <br />ing to the output signal. Model PT322 transmitter shall <br />operate on 12-30VDCNAC power (using PTPWRSUPP <br />Power Supply.) Models shall be provided in epoxy filled <br />enclosures. The Pulse Output Transmitter shall be Rain <br />Bird Model PT322. <br />Model PT3002 Pulse Transmitter/FlowMonitor <br />The flow monitor shall be a microprocessor based digital <br />unit capable of calculating and displaying both rate of <br />flow and total flow on a two line by sixteen character <br />alpha -numeric LCD. The flow monitor shall accept digital <br />inputs or optional sine wave or analog signal and may <br />be field configured to display rate and total values in <br />any unit of measure. NI data shall be entered via five <br />keys mounted on the front panel.The monitor shall <br />feature a software lock to protea the entered data from <br />unauthorized changes. A nonvolatile memory, requiring <br />no battery backupshall protect the data from electronic <br />losses. The Model PT3002 shall conform to DIN standard <br />dimensions for panel mounting, and shall feature a <br />NEMA 4X rated front panel, in an optional NEMA 4 wall <br />mount cabinet (NFMACAB). Monitor shall operate on <br />power of 12-24 VAC/VDC (using PTPW RSUPP Power <br />Supply.)The flow monitor shall feature standard open <br />collector transistor outputs, one based on rate and one <br />based on total. Setpoints or time delays for rate, scaling <br />or pulse width for total may be configured in the field. <br />Options shall include analog inputs, analog output or <br />control relays, all programmable from the keypad. The <br />flow monitor shall be Rain Bird Model PT3002. <br />Tefzei' is a registered tradernarkof DuPont <br />Rain Bird International, Inc. <br />1000 West Sierra Madre Ave. <br />Azusa, CA 91702 <br />Phone: (626) 963-9311 <br />Fax: (626) 852-7343 <br />The Intelligent Use ofWateC' <br />www.rainbird.com <br />D40785EO <br />