My WebLink
|
Help
|
About
|
Sign Out
Home
4A Public Hearings 2016 1121
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2016
>
Packet 2016 1121
>
4A Public Hearings 2016 1121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2016 5:07:38 PM
Creation date
11/16/2016 5:07:30 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
11/21/2016
Retention
PERM
Document Relationships
Reso 2016-153
(Reference)
Path:
\City Clerk\City Council\Resolutions\2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Page 5 of 6 <br /> <br />Section 903.2.9.1 and 903.2.9.2 remains. <br /> <br />903.2.10 Group S-2 Occupancies. <br /> <br />An automatic sprinkler system shall be provided throughout all buildings classified as <br />enclosed parking garages in accordance with Section 406.6 of the California Building <br />Code where either of the following conditions exists: <br /> <br />1. Where the fire area of the enclosed parking garage exceeds 7,500 square feet (697 <br />m2). <br />2. Where the enclosed parking garage is located beneath other groups. <br />3. When the overall height exceeds 45 feet. <br /> <br />Sections 903.2.10.1 is remains. <br /> <br />903.2.13 Group B Occupancies. <br /> <br />An automatic sprinkler system shall be installed in Group B occupancies where the floor <br />area exceeds 7,500 square feet (697 m²). <br /> <br />903.2.20 Group U Occupancies <br /> <br />An automatic sprinkler system shall be provided for Group U occupancies where the fire <br />area exceeds 7,500 square feet (697 m2). <br /> <br />903.6 Where required in existing buildings and structures <br />The provisions of this section are in addition to those requirements set forth in Chapter <br />11. Fire sprinklers shall be installed in existing commercial occupancy buildings when any <br />of the following exist: <br /> <br />1. Permits for additions and alterations increase the floor area by 25 percent. <br />2. Whenever an addition is made to an existing building causing the total square <br />footage of the building to exceed 7,500 square feet (465 m 2). The entire building <br />shall be equipped with sprinklers. <br />3. When a change in occupancy or use to a more hazardous occupancy type occurs. <br />The structure will be required to meet the requirements as set forth for new <br />construction for the new occupancy classification. <br /> <br />In residential occupancies, fire sprinklers shall be installed when there is an addition that <br />results in the square footage exceeding 3,600 square feet (334 m 2) including any <br />attached U occupancies or garages. <br /> <br />FINDING: The amendment is needed due to local climatic and topographical <br />conditions. <br /> <br />These modifications are necessary because the City has a dry period of at <br />least five months each year. Additionally, The area is subject to occasional <br />drought. Because of dryness, a rapidly burning grass fire or exterior <br />building fire can quickly transfer to other buildings. <br />
The URL can be used to link to this page
Your browser does not support the video tag.