Laserfiche WebLink
and repaired, or vacated and demolished or removed, whenever the Building Official or such <br />owner is engaged in repairing, vacating and repairing, or demolishing any such unsafe building <br />pursuant to this Chapter, or is performing any necessary act preliminary to or incidental to such <br />work, or authorized or directed pursuant hereto. <br />116.7.8.5 Prosecution. <br />In case the owner shall fail, neglect or refuse to comply with the notice to repair, rehabilitate, or <br />to demolish and remove said building or structure or portion thereof, the Building Official shall <br />cause the owner of the building to be prosecuted as a violator of this Code. <br />Section 7-5-110: REFERENCED STANDARDS AND APPENDICES. Referenced Standards <br />and Appendices in this Code are not adopted, but authorized for use by the Building Official. <br />Section 7-5-115: BOARD OF APPEALS. The Board of Appeals created under Section 7-5-113 <br />of the San Leandro Building Code shall hear and decide appeals of orders, decisions or <br />determinations made by the Building Official relative to the application and interpretation of this <br />Code. The Board shall function as described in said Section of the San Leandro Building Code. <br />Section 7-5-130: PEDESTRIAN WALKWAYS OVER PUBLIC PROPERTY. Pedestrian <br />walkways over public property shall be subject to the approval of the City. Notwithstanding the <br />preceding sentence, sidewalk arcades on public property in an established redevelopment project <br />area need not be considered as adjacent buildings for the provisions of this Chapter, provided <br />that the arcades are of not less than one (1) hour fire resistive construction or are constructed <br />entirely of noncombustible materials, fire retardant treated wood or heavy timber construction <br />with two-inch (2") nominal sheathing, or a combination of the above materials. <br />Section 7-5-135 <br />RESERVED <br />Section 7-5-140 Table R602.10.3 (3) Bracing Requirements Based on Seismic Design <br />Category) of CRC Chapter 6 (Wall Construction) is amended as follows: <br />Add a new "f' footnote notation to the end of CRC Table R602.10.3 (3). To read: <br />f. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted and <br />the use of Method PCP is limited to one-story single family dwellings and <br />accessory structures. <br />Add the "f' footnote notation in the title of Table R602.10.3 (3) to read: <br />TABLE R602.10.3 (3)f <br />Subsection R602.10.4.4, to read: <br />ORDINANCE NO. 2016-014 31 <br />