Laserfiche WebLink
2. A Group M fire area is located more than three stories above grade plane. <br />3. The combined area of all Group M fire areas on all floors, including any mezzanines, <br />exceeds 7,500 square feet (697 m2). <br />4. A Group M occupancy used for the display and sale of upholstered furniture or <br />mattresses exceeds 5,000 square feet (465 m2). <br />5. [SFM] The structure exceeds 7,500 square feet (697 m2), contains more than one fire <br />area containing a Group M occupancy, and is separated into two or more buildings by <br />fire walls of less than 4 -hour fire -resistance rating without openings. <br />6. When the overall height of the building exceeds 45 feet. <br />903.2.7.1 High -piled storage—Amended. <br />An automatic sprinkler system shall be provided as required in Chapter 32 in all buildings <br />of Group M where storage of merchandise is in high -piled or rack storage arrays. <br />903.2.9 Group S-1—Amended. <br />An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 <br />occupancy where one of the following conditions exists: <br />1. A Group S-1 fire area exceeds 7,500 square feet (697 m2). <br />2. A Group S-1 Fire area is located more than three stories above grade plane. <br />3. The combined area of all Group S-1 fire areas on all floors, including any <br />mezzanines, exceeds 5,000 square feet (2230 m2). <br />4. A Group S-1 Fire area used for the storage of commercial motor vehicles where the <br />fire area exceeds 5,000 square feet (464 m2). <br />5. A Group S-1 occupancy used for the storage of upholstered furniture or mattresses <br />exceeds 2,500 square feet (232 m2). <br />6. When the overall height of the building exceeds 45 feet. <br />903.2.9.1 Repair garages. <br />An automatic sprinkler system shall be provided throughout all buildings used as repair <br />garages in accordance with Section 406.8 of the California Building Code, as shown: <br />1. Buildings having two or more stories above grade plane, including basements, <br />with a fire area containing a repair garage exceeding 7,500 square feet (697 <br />m2). <br />2. Buildings not more than one story above grade plane, with a fire area <br />containing a repair garage exceeding 7,500 square feet (697 m2). <br />3. Buildings with repair garages servicing vehicles parked in basements. <br />4. A Group S-1 fire area used for the repair of commercial motor vehicles where <br />the fire area exceeds 5,000 square feet (465 m2). <br />903.2.9.2 Bulk storage of tires. <br />ORDINANCE NO. 2016-023 <br />6 <br />