Laserfiche WebLink
D. Driveway and Sidewalk Construction. Building Pen-nit plans shall show that the <br /> driveway and sidewalk construction shall be in compliance with the City of San Leandro <br /> Standard plans Dwg.No. 102, case 3 101 and Dwg. No. 100,case 3 10 1. <br /> E. Drainage Plan. Building Permit plans shall include drainage plan for site drainage and <br /> the plan shall show that the hardscape will be sloped to drain towards Pacific Avenue. <br /> F. Surface Elevations. Building Permit plans shall show proposed and existing surface <br /> elevations along property lines every 30 feet. <br /> G. Sewer. Building Permit plans show sanitary sewer lateral connections to the offsite sewer <br /> main pipeline.The City will inspect any defects in this sanitary sewer segment on Pacific <br /> Avenue and if the new lateral connection will cause any structural damage to the sanitary <br /> sewer main line, the applicant shall replace the main pipeline from joint to joint as part <br /> of this project prior to making the sewer lateral connection. <br /> . ............... <br /> H. Water Heater Drain Lines. Building permit plans shall show that the water heater drain <br /> lines shall be directly or indirectly connected to the sanitary sewer system and may not <br /> discharge to the storm drain system. <br /> I. Underground Utilities. Building permit plans shall show that all new electric and <br /> communications utilities serving the site are located underground. <br /> I Stormwater. The site is considered a small project per Alameda County C.3 Stormwater <br /> Technical Guidance.As per Appendix L"Site Design Requirements for Small Projects", <br /> the project must implement at least one of the following site design measures: <br /> • Direct roof runoff into cisterns or rain barrels for use. <br /> • Direct roof runoff onto vegetated areas. <br /> • Direct runoff from sidewalks,walkways, and/or patios onto vegetated areas. <br /> Direct runoff from driveways/uncovered parking lots onto vegetated areas. <br /> Construct sidewalks,walkways, and/or patios with permeable surfaces. <br /> Construct bike lanes, driveways, and/or uncovered parking lots with permeable <br /> surfaces. <br /> K. The applicant shall reduce storm water pollution by implementing the following <br /> pollution source control measures: <br /> • Structures shall be designed to discourage the occurrence and entry of pests into <br /> buildings,thus minimizing the need for pesticides.The trash area shall be separated <br /> from the rest of the building by concrete or masonry walls so that pests that gain <br /> access to the area are less likely to access the rest of the building. <br /> ® Sidewalks and parking lots shall be swept regularly to minimize the accumulation <br /> of litter and debris. Steam cleaning or low volume pressure washing may be <br /> performed only after pre-cleaning using dry methods, spot cleaning and recovery <br /> in stained areas and removal of all mobile pollutants.Debris resulting from pressure <br /> washing shall be trapped and collected to prevent entry into the storm drain system. <br /> Agreement to Conditions June 7, 2017 <br /> PLN17-0010 1514 Pacific Avenue Page 5 of 8 <br />