Laserfiche WebLink
u. Retail Services <br />v. Secondhand Sales <br />w. Supermarkets <br />3. LIMITATIONS ON PERMITTED OPERATIONS <br />Businesses may conduct their permitted business operations in an <br />Outdoor Business Area, subject to the limitations in this section. <br />a. Outdoor Business Areas shall be designed to maintain clear existing legal <br />exits from the building to the public way. A minimum 44 -inch wide exit path <br />must be maintained from the building and Outdoor Business Area. <br />b. Outdoor Business Areas with an occupancy greater than 50 require two <br />exits. <br />c. Outdoor Business Areas shall comply with ADA requirements. <br />d. A separate review, approval, and issuance of a fire code operational <br />permit by the Alameda County Fire Department (ACFD) is required <br />for tents open on all sides with a cumulative total floor area of 700 <br />square feet or more and/or tents with one side or more in excess of <br />400 square feet to ensure compliance with 2019 California Fire Code <br />Requirements as adopted by the City of San Leandro. <br />e. Flames of any type shall not be used in the Outdoor Business Area, <br />including, without limitation, stoves, burners and candles, with the <br />sole exception of heat lamps located outside of tents or canopies. <br />f. Heating units shall have a UL or AGA listing. Heating units shall not be <br />installed over or near exits from the building. Units shall maintain the <br />required clearances from combustible materials. A minimum of 6'8" <br />headroom clearance shall be maintained under heating unit. <br />g. Cooking or food preparation shall not be allowed in the Outdoor Business <br />Area. <br />h. Generators — gas or diesel — shall not be used in the Outdoor Business <br />Area. <br />i. Electrical extension cords may be used in the Outdoor Business Area <br />subject to the following: <br />i. Extension cords shall be listed and labeled as outdoor rated in <br />accordance with UL 817; <br />ii. Extension cords shall be plugged into an outlet with a GFI <br />protected circuit; <br />iii. Extension cords shall be secured in a manner that is compliant <br />with ADA accessibility standards, does not impede any person's <br />path of travel and does not constitute a tripping hazard; and <br />iv. Extension cords shall be disconnected from their electrical sources <br />each day at the conclusion of operations in the Outdoor Business <br />Area. <br />Only tables, chairs, benches, umbrellas, other moveable furniture and <br />barriers required by ABC may be placed in an Outdoor Business Area and <br />shall be subject to the following: <br />i. Items placed in the Outdoor Business Area shall be set back a <br />minimum of five feet (5') from building corners; <br />A-2 <br />