My WebLink
|
Help
|
About
|
Sign Out
Home
5A Public Hearings 2020 0928
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2020
>
Packet 2020 0928
>
5A Public Hearings 2020 0928
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2020 4:00:27 PM
Creation date
9/23/2020 12:20:20 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
9/28/2020
Retention
PERM
Document Relationships
Reso 2020-121 Climatec LLC Implementation and Construction Grand 59352113
(Approved)
Path:
\City Clerk\City Council\Resolutions\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
www.sulzer.com <br />SPP id: 2.1.2017 / en / e10429 / 1, Copyright © Sulzer Ltd 2017 <br />This document does not provide a warranty or guarantee of any kind. Please contact us for a description of the warranties and guarantees offered with our products. Directions for <br />use and safety will be given separately. All information herein is subject to change without notice. <br />HST 20-4500-1-U150 HST 20-4500-1-U200 HST 20-6000-1-U150 HST 20-6000-1-U200 HST 20-6000-1-U250 <br />Air flow range [scfm]1100-3600 1100-3700 1300-4400 1300-4500 1300-4700 <br />Pressure rise [psi]4.4-13.3 4.4-13.3 4.4-10.9 4.4-13.3 4.4-13.3 <br />Noise level [dB]61 62 60 62 62 <br />Input power [hp]150 200 150 200 250 <br />Power supply [V]460-600 460-600 460-600 460-600 460-600 <br />Input power frequency [Hz]50/60 50/60 50/60 50/60 50/60 <br />480 VMax. input current [A] (2) <br />Cable size [AWG or MCM] <br />Fuse size [A] <br />148 <br />3x3/0+1 <br />160 <br />197 <br />3x4/0+1/0 <br />200 <br />148 <br />3x3/0+1 <br />160 <br />197 <br />3x4/0+1/0 <br />200 <br />246 <br />3x300+3/0 <br />250 <br />580 VMax. input current [A] (2) <br />Cable size [AWG or MCM] <br />Fuse size [A] <br />122 <br />3x1/0+3 <br />125 <br />163 <br />3x4/0+1/0 <br />200 <br />122 <br />3x1/0+3 <br />125 <br />163 <br />3x4/0+1/0 <br />200 <br />204 <br />3x300+3/0 <br />250 <br />Weight [lb]2690-2890 2690-2890 2780-2975 2780-2975 2975 <br />(2) The maximum input current is calculated using the nominal voltage. The cable and fuse sizes are recommendations and based on the supply current and cables <br />rated to 70 °C [158 °F]. <br />Installation Conditions (1) <br />Altitude <br />Maximum altitude 8200 ft above sea level <br />Air quality <br />Permitted chemical vapors IEC 60721-3-3 class 3C3 <br />Ambient conditions <br />Ambient temperature range (1)Min. 14 °F, max. +113 °F <br />Ambient relative humidity < 95 %, non-condensing, non- <br />corrosive, no dripping water <br />Inlet conditions <br />Air temperature range for process <br />air taken from the room Min. 14 °F, max. +113 °F <br />Air temperature range for ducted <br />process air inlet (option)Min. -4 °F, max. +113 °F <br />(1) Sulzer may approve applications outside these criteria. <br />Compressor Data <br />Options <br />Various options for handling special requirements regarding e.g., <br />temperature, dusty environments and locations with high moisture <br />can be selected. <br />Accessories <br />Required accessories for installation such as flexible joints, valves, <br />silencers, and air filters are available from Sulzer. <br />Performance Testing <br />Compressor performance tests are performed on every machine <br />manufactured and certificates issued to confirm compliance. The <br />tests are carried out at the Sulzer factory test facility. Performance <br />is guaranteed with a manufacturing tolerance of ± 2% and a <br />measurement tolerance according to ISO 5389. Optionally tests can <br />be performed according to ISO 5389 or ASME PTC 10. The test can <br />be witnessed by the customer or a third party inspector. <br />Certification and Standards <br />The compressor is certified according to the relevant UL and CSA <br />standards: <br />• UL 1450 <br />• CSA C22.2 No. 68 <br />The product is designed and manufactured in accordance with EN <br />61800-3 standard and intended for use in second environment <br />locations, e.g., in industrial areas.77.8 in84.5 in49.4 in <br />38
The URL can be used to link to this page
Your browser does not support the video tag.