My WebLink
|
Help
|
About
|
Sign Out
Home
Reso 2002-125
CityHall
>
City Clerk
>
City Council
>
Resolutions
>
2002
>
Reso 2002-125
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2022 1:11:40 PM
Creation date
7/29/2022 1:09:15 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Resolution
Document Date (6)
12/31/2002
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT D TO RESOLUTION NO.2002 -125 <br />FINDINGS AND DETERMINATION THAT CHANGES <br />OR MODIFICATIONS TO THE UNIFORM BUILDING CODE, <br />AND THE CALIFORNIA BUILDING CODE, 2001 EDITION, <br />ARE REASONABLY NECESSARY BECAUSE OF LOCAL CONDITIONS <br />1. In connection with the adoption by reference of the Uniform Building Code, 1997 <br />Edition, and the Uniform Code for Building Conservation, 1997 Edition, as amended by the State <br />of California in that document entitled "The California Building Standards Code," it is hereby <br />expressly found and determined that the following changes found in San Leandro Municipal <br />Code Chapter 7-5, Articles 1 and 8 are reasonably necessary because of local climatic, geological <br />or topographical conditions: <br />Section 7-5-180: SEISMIC ZONE 4 NEAR -SOURCE FACTOR. Section 1629.4.2 of <br />the Code is deleted and replaced with the following: <br />In Seismic Zone 4, each site shall be assigned a near -source factor in accordance with Table 16-S and <br />the Seismic Source Type set forth in Table 16-U. The value ofNQ used in determining C,, need not <br />exceed 1.1 for structures complying with all the following conditions: <br />1. The soil profile type is Sg, SB, Sc or So. <br />2. p = 1.0. <br />3. Except in single -story structures, Group R, Division 3 and Group U, Division 1 <br />Occupancies, moment frame systems designated as part of the lateral -force -resisting system <br />shall be special moment -resisting frames. <br />4. The provisions in Sections 9.6a and 9.6b of AISC - Seismic Part 1 shall not apply, except <br />for columns in one-story buildings or columns at the top story of multistory buildings. <br />None of the following structural irregularities is present: Type 1, 4 or 5 of Table 16-L, and Type <br />1 or 4 of Table 16-M. <br />Section 7-5-181: STRUCTURAL SYSTEMS. Table 16-N of the California <br />Building Code is deleted and replaced with the following: <br />TABLE 16-N — STRUCTURAL SYSTEMS' <br />BASIC <br />LATERAL -FORCE -RESISTING SYSTEM <br />R <br />Q <br />HEIGHT <br />STRUCTURAL <br />DESCRIPTION <br />LIMIT FOR <br />SYSTEM2 <br />SEISMIC <br />ZONES 3 <br />AND 4 eet) <br />
The URL can be used to link to this page
Your browser does not support the video tag.