Location Existing Fixture Description kWQty Retrofit Code Description (Ltg control in RED)Hours kWh
<br />PRE-RETROFIT POST RETROFIT
<br />Qty kW SvdWt/Fxt kWh SvdHourskWhkWWt/Fxt
<br />Public Works -
<br /> (sorted by building, floor, area)
<br />City of San Leandro - Lighting Detail Report
<br />Building/Area:Admin Office
<br />1st Floor
<br />0.0661 3,120 34 3,12012x2x 2L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-1 Rm - entry lobby 206 0.034 106 0.032 10066RL0172/bx - (2) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.5288 3,120 34 3,12082x2x 2L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-2 Rm - reception
<br />desk area
<br />1,647 0.272 849 0.256 79966RL0172/bx - (2) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.464 2,700 51 2,70042x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-3 Rm - 1st office to
<br />left (CCW)
<br />1,242 0.204 551 0.256 691115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.464 2,700 51 2,70042x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-4 Rm - R Office 1,242 0.204 551 0.256 691115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.1773 3,120 24 3,12032x2x 2L rec trf pblc, FB31T8 32w,
<br />electronic ballast
<br /> Rf#-5 Rm - short hallway 552 0.072 225 0.105 32859RLT822udw - (3) 2' LED T8 "U" lamp 12w, Type B,
<br />Direct Wire, 50,000-Hr L70 rated life, remove existing
<br />0.3546 2,850 24 2,85062x2x 2L rec trf pblc, FB31T8 32w,
<br />electronic ballast
<br /> Rf#-6 Rm - break room 1,009 0.144 410 0.21 59859RLT822udw - (3) 2' LED T8 "U" lamp 12w, Type B,
<br />Direct Wire, 50,000-Hr L70 rated life, remove existing
<br />0.464 2,700 51 2,70042x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-7 Rm - Office 1,242 0.204 551 0.256 691115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.232 500 51 50022x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-8 Rm - storage 115 0.102 51 0.128 64115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.2955 3,120 24 3,12052x2x 2L rec trf pblc, FB31T8 32w,
<br />electronic ballast
<br /> Rf#-9 Rm - short hallway 920 0.12 374 0.175 54659RLT822udw - (3) 2' LED T8 "U" lamp 12w, Type B,
<br />Direct Wire, 50,000-Hr L70 rated life, remove existing
<br />0.696 2,700 51 2,70062x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-10 Rm - L Office 1,863 0.306 826 0.384 1,037115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.928 3,120 51 3,12082x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-11 Rm - short
<br />hallway
<br />2,870 0.408 1,273 0.512 1,597115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.2810 1,400 28 1,400101x4x 2L sm vapor tight, LED 14w?
<br />Type B, n/a
<br /> Rf#-12 Rm - M RR/locker 392 0.28 392 0 028DND - DND: (do not do, fixtures left as is)
<br />0.464 2,850 51 2,85042x2x 3L rec trf pblc, Biax 22", CF
<br />ballast
<br /> Rf#-13 Rm - Conf Room 1,311 0.204 581 0.256 730115RL0173/bx - (3) LED BIAX PL-L lamp, direct wire,
<br />120/277v, 17.5w, 22", 50,000-Hr L70 rated life
<br />0.2810 1,400 28 1,400101x4x 2L sm vapor tight, LED 14w?
<br />Type B, n/a
<br /> Rf#-14 Rm - W RR/locker 392 0.28 392 0 028DND - DND: (do not do, fixtures left as is)
<br />0.4239 2,850 21 2,85092x2x 3L rec trf pblc, F17T8 17w,
<br />electronic ballast
<br /> Rf#-15 Rm - Meeting
<br />Room
<br />1,206 0.189 539 0.234 66747RLT823dw - (3) 2' LED T8 lamp 9w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />0.0591 500 21 50011x4x 2L sm wp, F32T8 32w,
<br />electronic ballast
<br /> Rf#-16 Rm - Custodial 30 0.021 10 0.038 1959RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />0.0942 3,120 21 3,12022x2x 3L rec trf pblc, F17T8 17w,
<br />electronic ballast
<br /> Rf#-17 Rm - short hall
<br />to reception
<br />293 0.042 131 0.052 16247RLT823dw - (3) 2' LED T8 lamp 9w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />0.0942 2,700 21 2,70022x2x 3L rec trf pblc, F17T8 17w,
<br />electronic ballast
<br /> Rf#-18 Rm - Plans
<br />Printer Rm
<br />254 0.042 113 0.052 14047RLT823dw - (3) 2' LED T8 lamp 9w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />0.0942 2,700 21 2,70022x2x 3L rec trf pblc, F17T8 17w,
<br />electronic ballast
<br /> Rf#-19 Rm - Room to
<br />right of above
<br />254 0.042 113 0.052 14047RLT823dw - (3) 2' LED T8 lamp 9w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />0.091 2,700 32 2,70012x4x 3L sm box, F32T8 32w,
<br />electronic ballast
<br /> Rf#-20 Rm - Traffic
<br />Entry area
<br />243 0.0315 85 0.0585 15890RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />0.182 2,700 32 2,70022x4x 3L sm box, F32T8 32w,
<br />electronic ballast
<br /> Rf#-21 Rm - Office #1 486 0.063 170 0.117 31690RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, Direct
<br />Wire, 50,000-Hr L70 rated life, remove existing ballast
<br />Public Works Lighting Page 35W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control