Laserfiche WebLink
Location Existing Fixture Description kWQty Retrofit Code Description (Ltg control in RED)Hours kWh <br />PRE-RETROFIT POST RETROFIT <br />Qty kW SvdWt/Fxt kWh SvdHourskWhkWWt/Fxt <br />San Leandro Aquatic Center - <br /> (sorted by building, floor, area) <br />City of San Leandro - Lighting Detail Report <br />0.1442 500 21 50021x4x 2L sm vapor tight, F40T12 <br />34w, magnetic ballast <br /> Rf#-36 Rm - Custodial 72 0.042 21 0.102 5172RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct <br />Wire, 50,000-Hr L70 rated life, remove existing ballast <br />0.4326 500 21 50061x4x 2L sm vapor tight, F40T12 <br />34w, magnetic ballast <br /> Rf#-37 Rm - Snack bar 216 0.126 63 0.306 15372RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct <br />Wire, 50,000-Hr L70 rated life, remove existing ballast <br />0.1442 500 21 50021x4x 2L sm vapor tight, F40T12 <br />34w, magnetic ballast <br /> Rf#-38 Rm - Old B <br />RR/locker (now storage) <br />72 0.042 21 0.102 5172RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct <br />Wire, 50,000-Hr L70 rated life, remove existing ballast <br />0.126 500 10 5006CF 1L wm vandal, CFP-18w, CF <br />ballast <br /> Rf#-39 Rm - Old B <br />RR/locker (now storage) <br />60 0.06 30 0.06 3020NL010/sq - New LED surface mnt sq, 50,000-Hr L70 <br />rated life, 10w (ALE) <br />0.1442 500 21 50021x4x 2L sm vapor tight, F40T12 <br />34w, magnetic ballast <br /> Rf#-40 Rm - Old G <br />RR/locker (now storage) <br />72 0.042 21 0.102 5172RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct <br />Wire, 50,000-Hr L70 rated life, remove existing ballast <br />0.126 500 10 5006CF 1L wm vandal, CFP-18w, CF <br />ballast <br /> Rf#-41 Rm - Old G <br />RR/locker (now storage) <br />60 0.06 30 0.06 3020NL010/sq - New LED surface mnt sq, 50,000-Hr L70 <br />rated life, 10w (ALE) <br />0.1442 500 21 50021x4x 2L sm vapor tight, F40T12 <br />34w, magnetic ballast <br /> Rf#-42 Rm - storage #1 72 0.042 21 0.102 5172RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct <br />Wire, 50,000-Hr L70 rated life, remove existing ballast <br />0.1442 500 21 50021x4x 2L sm vapor tight, F40T12 <br />34w, magnetic ballast <br /> Rf#-43 Rm - storage #2 72 0.042 21 0.102 5172RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, Direct <br />Wire, 50,000-Hr L70 rated life, remove existing ballast <br />Building/Area:Pool Area <br />1st Floor <br />3.330 2,500 110 2,50030LED 1L show box GY (VIS BSX), LED <br />110w, LED Driver 0-10v <br /> Rf#-31 Rm - Ext - Pole <br />Mount <br />8,250 3.3 8,250 0 0110DND - DND: (do not do, fixtures left as is) <br />E-FSP211 <br />0.0541 4,380 54 4,3801LED 1L flood, cobra KM GY (VIS <br />BSX), LED 54w, LED Driver 0-10v <br /> Rf#-32 Rm - Ext - Pole <br />Mount <br />237 0.054 237 0 054DND - DND: (do not do, fixtures left as is) <br />E-FSP211 <br />0.28515 2,500 19 2,50015LED 1L flood, knuckle (Lith), LED <br />19w, n/a <br /> Rf#-33 Rm - Ext - Pole <br />Mount <br />713 0.285 713 0 019DND - DND: (do not do, fixtures left as is) <br />0.1622 4,380 81 4,3802LED 1L flood, KM BZ (VIS BSX), LED <br />81w, LED Driver 0-10v <br /> Rf#-34 Rm - Ext - Pole <br />Mount <br />710 0.162 710 0 081DND - DND: (do not do, fixtures left as is) <br />E-FSP211 <br />Building/Area:Tennis Courts <br />1st Floor <br />8.648 1,000 1080 1,0008MH 1L flood, tenon, MH 1000w?, <br />HID ballast <br /> Rf#-35 Rm - Ext - Pole <br />Mount <br />8,640 8.64 8,640 0 01080DND - DND: (do not do, fixtures left as is) <br />320 320Qty and kW for San Leandro Aquatic Center : 26.8 <br /> kWh for San Leandro Aquatic Center : 47,571 <br />17.5 <br />18,667 <br />9.3 <br />28,908 <br />San Leandro Aquatic Center Lighting Page 42W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control <br />DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8