Location Existing Fixture Description kWQty Retrofit Code Description (Ltg control in RED)Hours kWh
<br />PRE-RETROFIT POST RETROFIT
<br />Qty kW SvdWt/Fxt kWh SvdHourskWhkWWt/Fxt
<br />Water Pollution Control Plant -
<br /> (sorted by building, floor, area)
<br />City of San Leandro - Lighting Detail Report
<br />0.0968 3,000 12 3,0008LED 1L rec can 6", LED 22w?, n/a Rf#-14 Rm - Hallway
<br />North
<br />288 0.096 288 0 012DND - DND: (do not do, fixtures left as is)
<br />0.065 3,000 12 3,0005LED 1L rec can 6", LED 22w?, n/a Rf#-15 Rm - Copy File
<br />room
<br />180 0.06 180 0 012DND - DND: (do not do, fixtures left as is)
<br />0.325 3,000 12 3,00025LED 1L rec can 6", LED 22w?, n/a Rf#-16 Rm - Entrance &
<br />Reception Area
<br />900 0.3 900 0 012DND - DND: (do not do, fixtures left as is)
<br />0.0162 3,000 8 3,0002CF 1L pm custom (ESPEN V), LED
<br />8w 4/pin V, n/a
<br /> Rf#-17 Rm - Above
<br />Receptionist Desk
<br />48 0.016 48 0 08DND - DND: (do not do, fixtures left as is)
<br />0.0242 2,900 12 2,9002LED 1L rec can 6", LED 22w?, n/a Rf#-18 Rm - Unisex RR 70 0.024 70 0 012DND - DND: (do not do, fixtures left as is)
<br />0.2084 3,000 52 3,00041x8x 4L pm ind/dir (ESPEN), LED
<br />12w TLED, electronic ballast
<br /> Rf#-19 Rm - Conference
<br />room
<br />624 0.208 624 0 052DND - DND: (do not do, fixtures left as is)
<br />0.0968 3,000 12 3,0008LED 1L rec can 6", LED 22w?, n/a Rf#-20 Rm - Conference
<br />room
<br />288 0.096 288 0 012DND - DND: (do not do, fixtures left as is)
<br />0.1926 3,000 32 3,00062x4x 2L rec trf vol (ESPEN), LED
<br />13w TLED, electronic ballast
<br /> Rf#-21 Rm - Control
<br />Building Area
<br />576 0.192 576 0 032DND - DND: (do not do, fixtures left as is)
<br />0.1284 2,700 32 2,70042x4x 2L rec trf vol (ESPEN), LED
<br />13w TLED, electronic ballast
<br /> Rf#-22 Rm - Plant
<br />Manager Office
<br />346 0.128 346 0 032DND - DND: (do not do, fixtures left as is)
<br />0.1284 2,700 32 2,70042x4x 2L rec trf vol (ESPEN), LED
<br />13w TLED, electronic ballast
<br /> Rf#-23 Rm - Judy's
<br />Office
<br />346 0.128 346 0 032DND - DND: (do not do, fixtures left as is)
<br />0.1926 2,700 32 2,70062x4x 2L rec trf vol (ESPEN), LED
<br />13w TLED, electronic ballast
<br /> Rf#-24 Rm -
<br />Supervisor's office
<br />518 0.192 518 0 032DND - DND: (do not do, fixtures left as is)
<br />0.0442 2,700 22 2,70022x2x 2L rec trf vol (ESPEN),
<br />FP14/835, electronic ballast
<br /> Rf#-25 Rm - Lab Office 1 119 0.044 119 0 022DND - DND: (do not do, fixtures left as is)
<br />0.0884 2,700 22 2,70042x2x 2L rec trf vol (ESPEN),
<br />FP14/835, electronic ballast
<br /> Rf#-26 Rm - Lab Office 2 238 0.088 238 0 022DND - DND: (do not do, fixtures left as is)
<br />0.74834 3,000 22 3,000342x2x 2L rec trf vol (ESPEN),
<br />FP14/835, electronic ballast
<br /> Rf#-27 Rm - Lab 2,244 0.748 2,244 0 022DND - DND: (do not do, fixtures left as is)
<br />0.0884 3,000 22 3,00042x2x 2L rec trf vol (ESPEN),
<br />FP14/835, electronic ballast
<br /> Rf#-28 Rm - Lab Micro
<br />Biology room
<br />264 0.088 264 0 022DND - DND: (do not do, fixtures left as is)
<br />0.22824 4,380 10 4,38024CF 1L wm wall pack (GC), LED 9.5w
<br />4/pin, n/a
<br /> Rf#-29 Rm - Ext-Bldg
<br />Mnt
<br />999 0.228 999 0 09.5 DND - DND: (do not do, fixtures left as is)
<br />Building/Area:New FFR
<br />1st Floor
<br />0.186 4,380 30 4,3806LED 1L wm wall pack FCO (Syl), LED
<br />30w, n/a
<br /> Rf#-76 Rm - Ext - Wall
<br />Mount
<br />788 0.18 788 0 030DND - DND: (do not do, fixtures left as is)
<br />0.2084 4,380 52 4,3804LED 1L post top GY (VIS PGR), LED
<br />52w, LED Driver 0-10v
<br /> Rf#-77 Rm - Ext - Pole
<br />Mount
<br />911 0.208 911 0 052DND - DND: (do not do, fixtures left as is)
<br />E-FSP211
<br />0.124 500 30 5004LED 1L wm wall pack FT (Syl), LED
<br />30w?, n/a
<br /> Rf#-78 Rm - main
<br />electrical room
<br />60 0.12 60 0 030DND - DND: (do not do, fixtures left as is)
<br />Building/Area:Parking Lot
<br />1st Floor
<br />0.275 4,380 54 4,3805LED 1L flood, cobra KM GY (VIS
<br />BSX), LED 54w, LED Driver 0-10v
<br /> Rf#-30 Rm - Ext-Pole
<br />Mount
<br />1,183 0.27 1,183 0 054DND - DND: (do not do, fixtures left as is)
<br />E-FSP211
<br />Water Pollution Control Plant Lighting Page 50W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control