My WebLink
|
Help
|
About
|
Sign Out
Home
Reso 2025-152 Building Code Findings
CityHall
>
City Clerk
>
City Council
>
Resolutions
>
2025
>
Reso 2025-152 Building Code Findings
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2025 5:02:58 AM
Creation date
11/26/2025 5:01:58 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Resolution
Document Date (6)
11/17/2025
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 34 of 68 <br /> <br />Add a new “f” footnote notation to the end of CRC Table R602.10.3(3). To read: <br /> <br />f. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted and the use of <br />Method PCP is limited to one-story single-family dwellings and accessory structures. <br /> <br />Add the “f” footnote notation in the title of Table R602.10.3(3) to read: <br />TABLE R602.10.3(3)f <br />Subsection R602.10.4.4, to read: <br /> <br />R602.10.4.4 Limits on methods GB and PCP. In Seismic Design Categories D0, D1, and <br />D2, Method GB is not permitted for use as intermittent braced wall panels, but gypsum <br />board is permitted to be installed when required by this Section to be placed on the opposite <br />side of the studs from other types of braced wall panel sheathing. In Seismic Design <br />Categories D0, D1, and D2, the use of Method PCP is limited to one-story single-family <br />dwellings and accessory structures. <br /> <br /> <br /> <br />7-5-145 MULTIPLE HAZARDS: OUTDOOR STORAGE. <br /> <br />(a) When a hazardous material has multiple hazards, all hazards shall be addressed and <br />controlled in accordance with the provisions of this chapter. When overhead noncombustible <br />construction is provided for sheltering exterior hazardous material storage areas, such storage <br />shall not be considered indoor storage when all of the following conditions are met: <br /> <br />(1) Supports shall be of noncombustible construction. <br /> <br />(2) Supports and walls shall not obstruct more than twenty-five percent (25%) of the <br />perimeter of the storage area. <br /> <br />(3) The distance to buildings, property lines, streets, alleys, public ways or exits to a public <br />way shall not be less than the distance required for an exterior hazardous material storage area <br />without weather protection. <br /> <br />7-5-155 NONCOMBUSTIBLE CONSTRUCTION. <br /> <br />Section 414.6.1.3 of the 2025 California Building Code is added to read as follows: <br /> <br />414.6.1.3 Non-combustible construction. The overhead structure shall be of approved <br />noncombustible construction with a maximum area of 3,000 square feet (140m2). <br /> <br />7-5-160 MODIFICATIONS TO 2025 CBC AND ASCE 7. <br />Resolution No. 2025-152