My WebLink
|
Help
|
About
|
Sign Out
Home
Reso 2025-152 Building Code Findings
CityHall
>
City Clerk
>
City Council
>
Resolutions
>
2025
>
Reso 2025-152 Building Code Findings
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2025 5:02:58 AM
Creation date
11/26/2025 5:01:58 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Resolution
Document Date (6)
11/17/2025
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 48 of 68 <br /> <br />107.6 Refunds–Amended. <br /> <br />Shall be in accordance with the provisions in Section 109 of the San Leandro Building Code. <br /> <br />903.2.1.1 Group A-1–Amended. <br /> <br />An automatic sprinkler system shall be provided for fire areas containing Group A-1 occupancies <br />and intervening floors of the building where one of the following conditions exists: <br /> <br />1. The fire area exceeds 5,000 square feet (697 m2), or <br />2. The fire area has an occupant load of 300 or more, or <br />3. The fire area is located on a floor other than a level of exit discharge serving such <br />occupancies, or <br />4. The Fire area contains a multi-theater complex, or <br />5. When the overall height of the building exceeds 30 feet. <br /> <br />903.2.1.2 Group A-2-Amended. <br /> <br />An automatic sprinkler system shall be provided for fire areas containing Group A-2 occupancies <br />and intervening floors of the building where one of the following conditions exists: <br /> <br />1. The fire area exceeds 5,000 square feet (465 m2), or <br />2. The fire area has an occupant load of 100 or more, or <br />3. The fire area is located on a floor other than a level of exit discharge serving such <br />occupancies, or <br />4. When the overall height of the building exceeds 30 feet. <br />903.2.1.3 Group A-3–Amended. <br />An automatic sprinkler system shall be provided for fire areas contain Group A-3 occupancies <br />and intervening floors of the building where one of the following conditions exists: <br />1. The fire area exceeds 5,000 square feet (697 m2), or <br />2. The fire area has an occupant load of 300 or more, or <br />3. The fire area is located on a floor other than a level of exit discharge serving such <br />occupancies, or <br /> <br />903.2.1.4 Group A-4–Amended. <br /> <br />An automatic sprinkler system shall be provided for fire areas containing Group A-4 occupancies <br />and intervening floors of the building where one of the following conditions exists: <br /> <br />1. The fire area exceeds 5,000 square feet (697 m2), or <br />2. The fire area has an occupant load of 300 or more, or <br />3. The fire area is located on a floor other than a level of exist discharge serving such <br />occupancies, or <br />Resolution No. 2025-152
The URL can be used to link to this page
Your browser does not support the video tag.