caused by wind, in which case the design level shall be as required by the code in effect at the <br />time of original construction or as required by the building code, whichever is greater. Seismic <br />forces for this rehabilitation design shall be those required for the design of the predamaged <br />building, but not less than the reduced level seismic forces specified in Section 3403.6.1.1.3. <br />New structural members and connections required by this rehabilitation design shall comply with <br />the detailing provisions of the building code for new buildings of similar structure, purpose, and <br />location. <br />3403.6.2.3 Substantial structural damage to vertical load-carrying components. Vertical <br />load-carrying components that have sustained substantial structural damage shall be rehabilitated <br />to comply with the applicable provisions for dead and live loads in the building code. <br />Undamaged vertical load-carrying components that receive dead ar live loads from rehabilitated <br />components shall also be rehabilitated to carry the design loads of the rehabilitation design. New <br />structural members and connections required by this rehabilitation design shall comply with the <br />detailing provisions of the building code for new buildings of similar structure, purpose, and <br />location. <br />3403.6.2.3.1 Lateral force-resisting elements. Regardless of the level of damage to vertical <br />elements of the lateral force-resisting system, if substantial structural damage to vertical load- <br />carrying components was caused primarily by wind or seismic effects, then the building shall be <br />evaluated in accordance with Section 3403.6.2.2.1 and, ifnon-compliant, rehabilitated in <br />accordance with Section 3403.6.2.2.3. <br />3403.6.2.4 Less than substantial structural damage. For damage less than substantial <br />structural damagE, repairs shall be allowed that restore the building to its pre-damage state, using <br />materials and strengths that existed prior to the damage. New structural members and <br />connections used for this repair shall comply with the detailing provisions of the building code <br />for new buildings of similar structure, purpose, and location. <br />8 <br />