My WebLink
|
Help
|
About
|
Sign Out
Home
3A Public Hearing 2007 1105
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2007
>
Packet 2007 1105
>
3A Public Hearing 2007 1105
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2008 12:46:27 PM
Creation date
11/2/2007 2:54:52 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
5/11/2007
Retention
PERM
Document Relationships
_CC Agenda 2007 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1105
8D Consent 2007 1001
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1001
Ord 2007-022
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-023
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-024
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-025
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-026
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-027
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-028
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-029
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-030
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-031
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-032
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-033
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-034
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-035
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-036
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
136
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(a) General. All materials permitted by the Uniform Building Code including their <br />appropriate allowable stresses and those existing configurations of materials <br />specified herein maybe utilized to meet the requirements of this Article. <br />(b) Existing Materials. <br />(1) Unreinforced Masonry Walls. Unreinforced masonry walls analyzed in <br />accordance with this Article may provide vertical support for roof and <br />floor construction and resistance to lateral loads. The facing and backing <br />of such walls shall be bonded so that not less than 4 percent of the exposed <br />face area is composed of solid headers extending not less than 4 inches <br />into the backing. The distance between adjacent full-length headers shall <br />not exceed 24 inches vertically or horizontally. Where the backing <br />consists of two or more wythes the header shall extend not less than 4 <br />inches into the most distant wythe, or the backing wythes shall be bonded <br />together with separate headers whose area and spacing conform to the <br />foregoing. <br />Tension stresses due to seismic forces normal to the wall maybe <br />neglected if the walls do not exceed the height to thickness ratio in Table 2 <br />of this Article and the in-plane shear stresses due to seismic loads as set <br />forth in Table 3 of this Article, and the in-plane shear stresses due to <br />seismic loads as set forth in Table 4 of this Article. If the wall height- <br />thickness ratio exceeds the specified limits, the wall maybe supported by <br />vertical bracing members designed in accordance with Section 7-5-855. <br />The deflection of such bracing member at design loads shall not exceed <br />one-tenth of the wall thickness. <br />All vertical bracing members shall be attached to the floor and roof <br />construction for their design loads independently of required wall anchors. <br />Horizontal spacing of vertical bracing members shall not exceed one-half <br />the unsupported height of the wall nor ten feet. The wall height maybe <br />measured vertically to bracing elements other than a floor or roof. Spacing <br />of the bracing elements and wall anchors shall not exceed six feet. <br />Bracing elements shall be detailed to minimize the horizontal <br />displacement of the wall by components of vertical displacements of the <br />floor or roof. <br />(2) Existing Roof, Floors, Walls, Footings, and Wood Framing. Existing <br />materials including wood shear walls utilized in the described <br />configuration maybe used as part of the lateral load resisting system, <br />provided that the stresses in these materials do not exceed the values <br />shown in Table 4 of this Article. <br />ORDINANCE NO. 2007-030 E) <br />
The URL can be used to link to this page
Your browser does not support the video tag.