My WebLink
|
Help
|
About
|
Sign Out
Home
3A Public Hearing 2007 1105
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2007
>
Packet 2007 1105
>
3A Public Hearing 2007 1105
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2008 12:46:27 PM
Creation date
11/2/2007 2:54:52 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
5/11/2007
Retention
PERM
Document Relationships
_CC Agenda 2007 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1105
8D Consent 2007 1001
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2007\Packet 2007 1001
Ord 2007-022
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-023
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-024
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-025
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-026
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-027
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-028
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-029
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-030
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-031
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-032
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-033
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-034
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-035
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
Ord 2007-036
(Reference)
Path:
\City Clerk\City Council\Ordinances\2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
136
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(c) Strengtheni~ of Existing Materials. New materials including wood shear walls <br />maybe utilized to strengthen portions of the existing seismic resisting system in <br />the described configurations provided that the stresses do not exceed the values <br />shown in Table 5 of this Article. <br />(d) Alternative Materials. Alternative materials, designs and methods of construction <br />maybe approved by the Building Official in accordance with the provisions of the <br />Uniform Building Code. <br />(e) Minimum Acceptable Quality of Existing Unreinforced Masonry Walls. <br />(1) General Provisions. All unreinforced masonry walls utilized to carry <br />vertical loads and seismic forces parallel and perpendicular to the wall <br />plane shall be tested as specified in this subsection. All masonry quality <br />shall equal or exceed the minimum standards established herein or shall be <br />removed and replaced by new materials. Alternate methods of testing <br />maybe approved by the Building Official. The quality of mortar in all <br />masonry walls shall be determined by performing in-place shear tests or by <br />testing eight inch diameter cores. Alternative methods of testing maybe <br />approved by the Building Official. Nothing shall prevent pointing with <br />mortar of all the masonry wall joints before the tests are first made. Prior <br />to any pointing, the mortar joints must be raked and cleaned to remove <br />loose and deteriorated mortar. Mortar for pointing shall be Type S or N <br />except that masonry cements shall not be used. All preparation and mortar <br />pointing shall be done under the continuous inspection of a designated <br />special inspector. At the conclusion of the inspection, the inspector shall <br />submit a written report to the licensed engineer or architect responsible for <br />the seismic analysis of the building setting forth the result of the work <br />inspected. Such report shall be submitted to the Building Official for <br />approval as part of the structural analysis. All testing shall be performed <br />in accordance with the requirements specified in this subsection by a <br />testing agency approved by the Building Official. An accurate record shall <br />be kept of all such tests and of their locations in the building, and these <br />results shall be submitted to the Building Official for approval as part of <br />the structural analysis. <br />(2) Number and Location of Tests. The minimum number of tests shall be <br />two per wall or line of wall elements resisting a common force, or 1 per <br />1500 square feet of wall surface, with a minimum of eight tests in any <br />case. The exact test or core location shall be determined at the building <br />site by the licensed engineer or architect responsible for the seismic <br />analysis of the subject building. <br />(3) In-Place Shear Tests. The bed joints of the outer wythe of the masonry <br />shall be tested in shear by laterally displacing a single brick relative to the <br />ORDINANCE NO. 2007-030 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.