Laserfiche WebLink
The City has standard plans that indicate details of construction of many site <br />improvements. All work shown shall conform to the standard plans. <br />The City has a standard fire alarm control panel. All new fire alarm control panels shall <br />conform to the standard. <br />All fill under pavements, buildings, and other improvements shall be installed at 9S% <br />relative compaction. The plans shall reflect this. <br />Structural calculations shall be provided for the design of the vertical and lateral force <br />resisting systems. Calculations shall include the design of joists, rafters, beams, headers, <br />posts, columns, connections, footings, horizontal diaphragms, collectors, frames, braces, <br />walls (in and out of plane), supports, attachments, and all other items whose design is <br />controlled by building code requirements. Structural design shall be in accordance with <br />the California Building standards code and the SEAONC blue book. Where conflicts <br />exist, the more stringent shall apply. Allowable stresses for all materials shall be as <br />published in the UBC, CBC, NDS, AISC, or other nationally recognized source. ICBO <br />reports are acceptable. <br />The site shall be graded so that storm water does not drain to adjacent property. <br />Contractor shall make every effort to design a building that qualifies for maximum <br />rebates under the PG&E `savings by design' program. <br />The site work shall include a conduit from the electrical room to an existing manhole on <br />Manor, 204' west of the property for a future fiber optic cable. <br />Washington Manor Branch Library Page 9 of 22 <br />Group 4 Architecture CSA <br />