My WebLink
|
Help
|
About
|
Sign Out
Home
3B Public Hearing 2010 0119
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 0119
>
3B Public Hearing 2010 0119
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2010 9:53:31 AM
Creation date
1/14/2010 9:52:08 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
1/19/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 0119
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 0119
3B Public Hearing 2010 0119 Attachment
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 0119
Reso 2010-003
(Reference)
Path:
\City Clerk\City Council\Resolutions\2010
Reso 2010-004
(Reference)
Path:
\City Clerk\City Council\Resolutions\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Adopted 7/16/2001 -Effective 8/15/2001 City of San Leandro Zoning Code -Article 19 <br />(includes amendments effective through 2007) <br />9. The irri atq ion system shaCi be designed to ensure that the dynamic <br />pressure at each emission device is within the manufacturer's <br />recommended pressure range for optimal performance. <br />~0_ Sensors (rain, freeze, wind, etc.), either integral or auxiliary that <br />suspend or after irrigation operation during unfavorable weather <br />conditions shalt be required on all irrigation systems as appropriate <br />for local climatic conditions. Irrigation should be avoided during windy <br />ar freezing weather or during rain. <br />11, Manual shut-off valves (such as a gate valve ball valve, or butterfly <br />valved shall be required, as close as possible to the point of <br />connection of the water supply, to minimize water loss in case of an <br />emergency (such as a main line breaks or routine repair. <br />12~ Backflow prevention devices shall be required to protect the water <br />supply from contamination by the irrigation system. <br />~ 3. The irrigation system shall be designed to prevent runoff low head <br />drainage, overspray, or other similar conditions where irrigation water <br />flows onto non-targeted areas, such as adjacent property non- <br />irrigated areas, hardscapes roadways, or structures. <br />14. In mulched planting areas, the use of low volume irrigation is required <br />to maximize water infiltration into the root zone. <br />1 ~. SprinKler spacing shall be desi ned to achieve to achieve a uniform <br />precipitation rate with no overspray onto hardscapes. <br />16. Swing joints or other riser-protection components are required on all <br />risers subject to damage that are adjacent to high traffic areas. <br />17, Gheck valves ar anti-drain valves are required for all irrigation <br />systems. <br />18. Narrow or irregulari~shaped areas, including turf, less than eight (8~ <br />feet in width in any direction shall be irrigated with subsurface <br />irrigation or low volume irrigation system. Overhead irrigation shall <br />not be permitted within twenty-four (24) inches of any non-permeable <br />surface. Allowable irrigation within the setback from non-permeable <br />surfaces may include drip, drip line, or other low flow non-spray <br />technology. <br />19. For the efficient use of water, al[ irrigation schedules steal! be <br />developed, managed, and evaluated to utilize the minimum amount <br />of water required to maintain plant health. Irrigation scheduling shall <br />be regulated by automatic irrigation controllers. Overhead irrigation <br />shall be scheduled between 8:QQ p.m. and 10:Og a.m. unless weather <br />conditions prevent it. if aI[owable hours of irrigation differ from the <br />local water purveyor, the stricter of the two shall apply. Operation of <br />the .irrigation system outside the normal watering window is allowed <br />far auditing and system maintenance. <br />AR.19 <br />Page 13 of 198 <br />
The URL can be used to link to this page
Your browser does not support the video tag.