2.4. Seismic evaluation and design of soft, weak, or open -front wall conditions in <br /> multiunit residential buildings of wood construction in Occupancy Category 1 or 11 <br /> are permitted to be based on the procedures specified in Appendix Chapter A4. <br /> 2.5. Seismic evaluation and design of concrete buildings and concrete with masonry <br /> infill buildings in all Occupancy Categories are permitted to be based on the <br /> procedures specified in Appendix Chapter A5. <br /> 3. In accordance with ASCE 31 based on the applicable performance level as shown in <br /> Table 3403.6.1.1.2. <br /> 4. Those associated with the BSE -1 Earthquake FIa Level defined in ASCE 41 and the <br /> performance level as shown in Table 3403.6.1.1.2. Where ASCE 41 is used, the design <br /> spectral response acceleration parameters S. and S shall not be taken less than 75 <br /> percent of the respective design seismic coefficients 2.5C and C„ as defined in Tables 16- <br /> Q and 16 -R of the Uniform Building Code. <br /> 3403.6.1.2 Wind Design. Wind design of existing buildings shall be based on the procedures <br /> specified in the building code. <br /> 3403.6.2 Repairs to damaged buildings. Repairs to damaged buildings shall comply with this <br /> section. <br /> 3403.6.2.1 Unsafe conditions. Regardless of the extent of structural damage, unsafe conditions <br /> shall be eliminated. <br /> 3403.6.2.2 Substantial structural damage to vertical elements of the lateral— force - resisting <br /> system. A building that has sustained substantial structural damage to the vertical elements of its <br /> lateral- force - resisting system shall be evaluated and repaired in accordance with the applicable <br /> provisions of Section 3403.6.2.2.1 through 3403.6.2.2.3. <br /> 3403.6.2.2.1 Evaluation. The building shall be evaluated by a registered design professional, and <br /> the evaluation findings shall be submitted to the building official. The evaluation shall establish <br /> whether the damaged building, if repaired to its pre- damage state, would comply with the <br /> provisions of the building code. Wind forces for this evaluation shall be those prescribed in the <br /> building code. Seismic forces for this evaluation are permitted to be the reduced level seismic <br /> forces specified in Code Section 3403.6.1.1.3. <br /> 3403.6.2.2.2 Extent of repair for compliant buildings. If the evaluation establishes compliance <br /> of the pre - damage building in accordance with Section 3403.6.2.2.1, then repairs shall be <br /> permitted that restore the building to its pre - damage state, using materials and strengths that <br /> existed prior to the damage. <br /> 3403.6.2.2.3 Extent of repair for non - compliant buildings. If the evaluation does not establish <br /> 9 <br />