compliance of the pre - damage building in accordance with Section 3403.6.2.2.1, then the <br /> building shall be rehabilitated to comply with applicable provisions of the building code for load <br /> combinations including wind or seismic forces. The wind design level for the repair shall be as <br /> required by the building code in effect at the time of original construction unless the damage was <br /> caused by wind, in which case the design level shall be as required by the code in effect at the <br /> time of original construction or as required by the building code, whichever is greater. Seismic <br /> forces for this rehabilitation design shall be those required for the design of the predamaged <br /> building, but not less than the reduced level seismic forces specified in Section 3403.6.1.1.3. <br /> New structural members and connections required by this rehabilitation design shall comply with <br /> the detailing provisions of the building code for new buildings of similar structure, purpose, and <br /> location. <br /> 3403.6.2.3 Substantial structural damage to vertical load- carrying components. Vertical <br /> load- carrying components that have sustained substantial structural damage shall be rehabilitated <br /> to comply with the applicable provisions for dead and live loads in the building code. <br /> Undamaged vertical Toad- carrying components that receive dead or live loads from rehabilitated <br /> components shall also be rehabilitated to carry the design loads of the rehabilitation design. New <br /> structural members and connections required by this rehabilitation design shall comply with the <br /> detailing provisions of the building code for new buildings of similar structure, purpose, and <br /> location. <br /> 3403.6.2.3.1 Lateral force - resisting elements. Regardless of the level of damage to vertical <br /> elements of the lateral force - resisting system, if substantial structural damage to vertical load - <br /> carrying components was caused primarily by wind or seismic effects, then the building shall be <br /> evaluated in accordance with Section 3403.6.2.2.1 and, if non - compliant, rehabilitated in <br /> accordance with Section 3403.6.2.2.3. <br /> 3403.6.2.4 Less than substantial structural damage. For damage less than substantial <br /> structural damage, repairs shall be allowed that restore the building to its pre - damage state, using <br /> materials and strengths that existed prior to the damage. New structural members and <br /> connections used for this repair shall comply with the detailing provisions of the building code <br /> for new buildings of similar structure, purpose, and location. <br /> 10 <br />