My WebLink
|
Help
|
About
|
Sign Out
Home
Agmt 2010 Martin Industries Inc dba Climatech
CityHall
>
City Clerk
>
City Council
>
Agreements
>
2010
>
Agmt 2010 Martin Industries Inc dba Climatech
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2012 5:22:37 PM
Creation date
11/3/2010 9:52:47 AM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agreement
Document Date (6)
11/1/2010
Retention
PERM
Document Relationships
Reso 2010-135
(Approved by)
Path:
\City Clerk\City Council\Resolutions\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e. Device Fault <br /> f. Field Controller Bus - Normal Data Transmission <br /> g. Field Controller Bus - No Data Transmission <br /> h. Field Controller Bus - No Communication <br /> i. Sensor - Actuator Bus - Normal Data Transmission <br /> j. Sensor - Actuator Bus - No Data Transmission <br /> k. Sensor - Actuator Bus - No Communication <br /> 7. The FEC shall accommodate the direct wiring of analog and binary I/O field points. <br /> 8. The FEC shall support the following types of inputs and outputs: <br /> a. Universal Inputs - shall be configured to monitor any of the following: <br /> 0 Analog Input, Voltage Mode <br /> 0 Analog Input, Current Mode <br /> 0 Analog Input, Resistive Mode <br /> 0 Binary Input, Dry Contact Maintained Mode <br /> 0 Binary Input, Pulse Counter Mode <br /> b. Binary Inputs - shall be configured to monitor either of the following: <br /> 0 Dry Contact Maintained Mode <br /> 0 Pulse Counter Mode <br /> c. Analog Outputs - shall be configured to output either of the following <br /> 0 Analog Output, Voltage Mode <br /> 0 Analog Output, current Mode <br /> d. Binary Outputs - shall output the following: <br /> 0 24 VAC Triac <br /> e. Configurable Outputs - shall be capable of the following: <br /> 0 Analog Output, Voltage Mode <br /> 0 Binary Output Mode <br /> 9. The FEC shall have the ability to reside on a Field Controller Bus (FC Bus). <br /> a. The FC Bus shall be a Master - Slave/Token- Passing (MS/TP) Bus supporting <br /> BACnet Standard protocol SSPC -135, Clause 9. <br /> b. The FC Bus shall support communications between the FECs and the NAE. <br /> c. The FC Bus shall also support Input /Output Module (IOM) communications <br /> with the FEC and with the NAE. <br /> d. The FC Bus shall support a minimum of 100 IOMs and FECs in any <br /> combination. <br /> e. The FC Bus shall operate at a maximum distance of 15,000 Ft. between the <br /> FEC and the furthest connected device. <br /> 10. The FEC shall have the ability to monitor and control a network of sensors and <br /> actuators over a Sensor - Actuator Bus (SA Bus). <br /> a. The SA Bus shall be a Master - Slave/Token- Passing (MS/TP) Bus supporting <br /> BACnet Standard Protocol SSPC -135, Clause 9. <br /> b. The SA Bus shall support a minimum of 10 devices per trunk. <br /> Non - Professional Services Agreement between November 1, 2010 <br /> City of San Leandro and Martin Industries, Inc., DBA Climatech Page 24 of 28 <br />