My WebLink
|
Help
|
About
|
Sign Out
Home
3B Public Hearing 2010 1115
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1115
>
3B Public Hearing 2010 1115
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2010 9:36:14 AM
Creation date
11/10/2010 3:14:08 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
11/15/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1115
Ord 2010-013
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-014
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-015
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-016
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-017
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-018
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-019
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-020
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
area. The average shall be obtained from the total number of cores made. If test <br />specimens cannot be made from cores taken, then the shear value shall be reported <br />as zero. <br />(f) Testing of Shear Bolts One -fourth of all new shear bolts and dowels embedded in <br />unreinforced masonry walls shall be tested by a special inspector using a torque calibrated <br />wrench to the following minimum torques: <br />2" diameter bolts or dowels = 40 foot -lbs. <br />5/8" diameter bolts or dowels = 50 foot -lbs. <br />3/4" diameter bolts or dowels = 60 foot -lbs. <br />No bolts exceeding 3/4" shall be used. All bolt heads and nuts shall be installed over <br />malleable iron or plate washers when bearing on wood and heavy cut washers when <br />bearing on steel. <br />(g) Determination of Allowable Stresses for Design Methods Based on Test Results <br />(1) Design Shear Values. Design seismic in -plane shear stresses shall be <br />substantiated by tests performed as specified in subsection (e) (3) and (4), above. <br />Design stresses shall be related to test results obtained in accordance with Table 5 <br />of this Article. Intermediate values between 3 and 10 psi may be interpolated. <br />(2) Design Compression and Tension Values. Compression stresses for unreinforced <br />masonry having a minimum design shear value of 3 psi shall not exceed 100 psi. <br />Design tension values for unreinforced masonry shall not be permitted. <br />(h) Five percent of the existing rod anchors utilized as all or part of the required wall anchors <br />shall be tested in pullout by an approved testing laboratory. The minimum number tested <br />shall be four per floor, with two tests at walls with joists framing into the wall and two <br />tests at walls with joists parallel to the wall. The test apparatus shall be supported on the <br />masonry wall at a minimum distance of the wall thickness from the anchor tested. The <br />rod anchor shall be given a preload of 300 lbs. prior to establishing a datum for recording <br />elongation. The tension test load reported shall be recorded at one - eighth inch relative <br />movement of the anchor and the adjacent masonry surface. Results of all tests shall be <br />reported. The report shall include the test results as related to the wall thickness and joist <br />orientation. The allowable resistance value of the existing anchors shall be 40 percent of <br />the average of those tested anchors having the same wall thickness and joist orientation. <br />(i) Qualification tests for devices used for wall anchorage shall be tested with the entire <br />tension load carried on the enlarged head at the exterior face of the wall. Bond on the <br />part of the device between the enlarged head and the interior wall face shall be eliminated <br />for the qualification tests. The resistance value assigned the device shall be 20 percent of <br />the average of the ultimate loads. <br />ORDINANCE NO. 2010-018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.