My WebLink
|
Help
|
About
|
Sign Out
Home
3B Public Hearing 2010 1115
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2010
>
Packet 2010 1115
>
3B Public Hearing 2010 1115
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2010 9:36:14 AM
Creation date
11/10/2010 3:14:08 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
11/15/2010
Retention
PERM
Document Relationships
_CC Agenda 2010 1105
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2010\Packet 2010 1115
Ord 2010-013
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-014
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-015
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-016
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-017
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-018
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-019
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
Ord 2010-020
(Reference)
Path:
\City Clerk\City Council\Ordinances\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 7 -5 -865 INFORMATION REOUIRED ON PLANS <br />(a) General In addition to the seismic analysis required elsewhere in this Article, the <br />licensed engineer responsible for the seismic analysis of the building shall determine and <br />record the information required by this section on the approved plans. <br />(b) Construction Details. The following requirements with appropriate construction details <br />shall be made part of the approved plans: <br />(1) All unreinforced masonry walls shall be anchored at the roof level by tension bolts <br />through the wall as specified in Table Al -E of Appendix A or by approved <br />equivalent at a maximum anchor spacing of six feet. All unreinforced masonry <br />walls shall be anchored at all floors with tension bolts through the wall or by <br />existing rod anchors at the maximum anchor spacing of six feet. All existing rod <br />anchors shall be secured to the joists to develop the required forces. The Building <br />Official may require testing to verify the adequacy of the embedded ends of <br />existing rod anchors. Tests when required shall conform to Section 7 -5- <br />1155A(h). When access to the exterior face of the masonry wall is prevented by <br />proximity of an existing building, wall anchors conforming Table Al -E may be <br />used. <br />Alternative devices to be used in lieu of tension bolts for masonry wall anchorage <br />shall be tested as specified in Section 7 -5 -860. <br />(2) Diaphragm chord stresses of horizontal diaphragms shall be developed in existing <br />materials or by addition of new materials. <br />(3) Where trusses and beams other than rafters or joists are supported on masonry, <br />ledgers or columns shall be installed to support vertical loads of the roof or floor <br />members. <br />(4) Parapets and exterior wall appendages not capable of resisting the forces specified <br />in this Article shall be removed, stabilized or braced to insure that the parapets <br />and appendages remain in their original position. <br />(5) All deteriorated mortar joints in unreinforced masonry walls shall be pointed with <br />Type S or N mortar (Masonry cements shall not be used). Prior to any pointing, <br />the wall surface must be raked and cleaned to remove loose and deteriorated <br />mortar. All preparation and pointing shall be done under the continuous <br />inspection of a special inspector certified to inspect masonry or concrete. At the <br />conclusion of the project, the inspector shall submit a written report to the <br />Building Official setting forth the portion of work inspected. <br />(6) Repair details shall be prepared for any cracked or damaged unreinforced masonry <br />wall required to resist forces specified in Appendix A. <br />ORDINANCE NO. 2010-018 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.