701.1.2 ABS and PVC drainage piping installations are not allowed. <br /> D. Sections 701.2 - Materials of the Uniform Plumbing Code - is hereby deleted and replaced to <br /> read as follows: <br /> 701.2 Materials for drainage fittings shall be in accordance with the applicable standards <br /> referenced in Table 7 -1 of the same diameter as the piping served, except that ABS and <br /> PVC installations are not allowed, and such fittings shall be compatible with the type of <br /> pipe used. <br /> E. Section 903.1.2 - Materials of the Uniform Plumbing Code - is hereby deleted and replaced <br /> to read as follows: <br /> 903.1.2 ABS and PVC vent piping and fittings are not allowed. <br /> F. Section 1003.1 — Materials of the Uniform Plumbing Code — is hereby deleted and replaced to <br /> read as follows: <br /> 1003.1 Each trap, except for traps within an interceptor or similar device, shall be self - <br /> cleaning. Traps for bathtubs, showers, lavatories, sinks, laundry tubs, floor drains, urinals, <br /> drinking fountains, dental units, and similar fixtures shall be of standard design and <br /> weight and shall be of cast brass, cast iron, lead, PP, or other approved material. An <br /> exposed and readily accessible drawn -brass tubing trap, not less than 17 B&S Gauge <br /> (0.045 inch) (1.1 mm), may be used on fixtures discharging domestic sewage. <br /> G. Section 1101.3 — Material Uses — is hereby deleted and replaced to read as follows: <br /> 1101.3 Rainwater piping placed within the interior of a building or run within a vent or <br /> shaft shall be of cast iron, galvanized steel, wrought iron, brass, copper, lead, stainless <br /> steel 304 or 316L (stainless steel 304 pipe and fittings shall not be installed underground <br /> and shall be kept at least six inches (152 mm) aboveground), or other approved materials, <br /> and changes in direction shall conform to the requirements of Section 706.0. <br /> H. Section 1102.1.2 - Materials of the Uniform Plumbing Code - is hereby deleted and replaced <br /> to read as follows: <br /> 1102.1.2 The inside of conductors installed above ground level shall be of seamless <br /> copper water tube, Type K, L, or M; Schedule 40 copper pipe or Schedule 40 copper alloy <br /> pipe; Type DWV copper drainage tube; service weight cast -iron pipe or hubless cast -iron <br /> soil pipe; standard weight galvanized steel pipe; stainless steel 304 or 316L (stainless <br /> steel 304 pipe and fittings shall not be installed underground and shall be kept at least 6 <br /> inches (152 mm) aboveground). <br /> ORDINANCE NO. 2010 -019 3 <br />