My WebLink
|
Help
|
About
|
Sign Out
Home
8F Consent 2013 1021
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2013
>
Packet 2013 1021
>
8F Consent 2013 1021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2013 9:19:33 AM
Creation date
10/16/2013 4:08:12 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
10/21/2013
Retention
PERM
Document Relationships
_CCAgenda 2013 1021 RG
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2013\Packet 2013 1021
MO 2013-051
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2013
Reso 2013-135
(Reference)
Path:
\City Clerk\City Council\Resolutions\2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
8 <br /> <br />TABLE 3405.2.4.1 <br /> <br />PERFORMANCE CRITERIA FOR CBC LEVEL SEISMIC FORCES <br /> <br />OCCUPANCY <br />CATEGORY <br />(BASED ON CBC <br />TABLE 1604.5) <br />PERFORMANCE LEVEL <br />FOR USE WITH <br />ASCE 41 BSE-1 <br />EARTHQUAKE <br />HAZARD LEVEL <br />PERFORMANCE <br />LEVEL FOR USE <br />WITH ASCE 41 BSE-2 <br />EARTHQUAKE <br />HAZARD LEVEL <br />I Life Safety (LS) Collapse Prevention (CP) <br />II Life Safety (LS) Collapse Prevention (CP) <br />III Note a Note a <br />IV Immediate Occupancy (IO) Life Safety (LS) <br />a. Acceptance criteria for Occupancy Category III shall be taken as 80 percent of the <br />acceptance criteria specified for Occupancy Category II performance levels, but <br />need not be less than the acceptance criteria specified for Occupancy Category IV <br />performance levels. <br /> <br />3405.2.4.2 Compliance with reduced CBC level seismic forces. Where seismic <br />evaluation and design is permitted to meet reduced California Building Code seismic <br />force levels, the procedures used shall be in accordance with one of the following: <br />1. The California Building Code using 75 percent of the prescribed forces. <br />Values of R, Ωo , and C d used for analysis shall be as specified in Section <br />3405.2.4.1 Item 1. <br />2. Structures or portions of structures that comply with the requirements of <br />the applicable chapter in Appendix A of the International Existing <br />Building Code as specified in Items 2.1 through 2.5 below shall be <br />deemed to comply with this section. <br />2.1. The seismic evaluation and design of unreinforced masonry bearing <br />wall buildings in Occupancy Category I or II are permitted to be <br />based on the procedures specified in Appendix Chapter A1. <br />2.2. Seismic evaluation and design of the wall anchorage system in <br />reinforced concrete and reinforced masonry wall buildings with <br />flexible diaphragms in Occupancy Category I or II are permitted to <br />be based on the procedures specified in Appendix Chapter A2. <br />2.3. Seismic evaluation and design of cripple walls and sill plate <br />anchorage in residential buildings of light-frame wood construction