My WebLink
|
Help
|
About
|
Sign Out
Home
8F Consent 2013 1021
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2013
>
Packet 2013 1021
>
8F Consent 2013 1021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2013 9:19:33 AM
Creation date
10/16/2013 4:08:12 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
10/21/2013
Retention
PERM
Document Relationships
_CCAgenda 2013 1021 RG
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2013\Packet 2013 1021
MO 2013-051
(Reference)
Path:
\City Clerk\City Council\Minute Orders\2013
Reso 2013-135
(Reference)
Path:
\City Clerk\City Council\Resolutions\2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
9 <br /> <br />in Occupancy Category I or II are permitted to be based on the <br />procedures specified in Appendix Chapter A3. <br />2.4. Seismic evaluation and design of soft, weak, or open-front wall <br />conditions in multiunit residential buildings of wood construction in <br />Occupancy Category I or II are permitted to be based on the <br />procedures specified in Appendix Chapter A4. <br /> 2.5. Seismic evaluation and design of concrete buildings in all <br />Occupancy Categories are permitted to be based on the procedures <br />specified in Appendix Chapter A5. <br />3. Compliance with ASCE 31 based on the applicable performance level as <br />shown in Table 3405.2.4.2. It shall be permitted to use the BSE-1 <br />earthquake hazard level as defined in ASCE 41 and subject to the <br />limitations in item 4 below. <br />4. Compliance with ASCE 41 using the BSE-1 Earthquake Hazard Level <br />defined in ASCE 41 and the performance level as shown in Table <br />3405.2.4.2. The design spectral response acceleration parameters S xs and <br />S x1 specified in ASCE 41shall not be taken less than 75 percent of the <br />respective design spectral response acceleration parameters S DS and S D1 <br />defined by the California Building Code and its reference standards. <br /> <br />TABLE 3405.2.4.2 <br />PERFORMANCE CRITERIA FOR REDUCED CBC <br />LEVEL SEISMIC FORCES <br /> <br />OCCUPANCY <br />CATEGORY <br />(BASED ON CBC TABLE <br />1604.5) <br />PERFORMANCE <br />LEVEL <br />FOR USE WITH ASCE <br />31 <br />PERFORMANCE LEVEL <br />FOR USE WITH ASCE <br />41 BSE-1 <br />EARTHQUAKE <br />HAZARD LEVEL <br />I Life Safety (LS) Life Safety (LS) <br />II Life Safety (LS) Life Safety (LS) <br />III Note a, Note b Note a <br />IV Immediate Occupancy (IO) Immediate Occupancy (IO) <br />a. Acceptance criteria for Occupancy Category III shall be taken as 80 percent of <br />the acceptance criteria specified for Occupancy Category II performance <br />levels, but need not be less than the acceptance criteria specified for <br />Occupancy Category IV performance levels. <br />b. For Occupancy Category III, the ASCE screening phase checklists shall be <br />based on the life safety performance level. <br />
The URL can be used to link to this page
Your browser does not support the video tag.