My WebLink
|
Help
|
About
|
Sign Out
Home
4A Public Hearing 2016 0516
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2016
>
Packet 2016 0516
>
4A Public Hearing 2016 0516
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 9:04:41 AM
Creation date
5/11/2016 5:29:31 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Staff Report
Document Date (6)
5/16/2016
Retention
PERM
Document Relationships
_CC Agenda 2016 0516 CS+RG
(Reference)
Path:
\City Clerk\City Council\Agenda Packets\2016\Packet 2016 0516
Reso 2016-054
(Reference)
Path:
\City Clerk\City Council\Resolutions\2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
SPECIFIC MEASUREMENT AND VERIFICATION PLAN <br />"OPTION A" <br />FOR HVAC SYSTEMS INSTALLATION <br />Introduction <br />This Measurement and Verification Plan (M&V) is specific to the installation of new high efficiency HVAC units and <br />chiller at the sites listed in the Table of Recommended Measures located at the beginning of this Attachment. <br />M&V Protocol <br />For this FEM, IPMVP Protocol — Option A shall be utilized. This option shall provide for the measurement of at <br />least one variable pre and post retrofit with other variables allowed for stipulation. For this retrofit, field data shall be <br />collected which includes, unit counts, unit tonnage, nameplate horsepower and efficiency rating for each existing <br />HVAC system. <br />Stipulated Values <br />Hours of Operation, heating/cooling loads and runtime hours of the existing HVAC systems are stipulated for <br />purposes of M & V. Please refer to Attachment C, HVAC Standards of Operation in this agreement for specific <br />operating hours and runtime hours for each HVAC unit or area. Stipulated values are agreed to by Purchaser. <br />Calculations <br />The calculations for the baseline energy consumption and post -retrofit savings provide the basis for the overall <br />financial viability of these FEM's. The following equations summarize the calculation of savings: <br />Electric (kWh) Savings <br />The electrical usage reduction of this FEM is determined by the following equation: <br />((Size of Existing HVAC Unit) x (Unit Efficiency) x (Stipulated Load Factor) - (Size of New Cooling Unit) x <br />(Unit Efficiency) x (Stipulated Load Factor)) x (Annual Operating Hours) = kWh Savings <br />Dollar Savings <br />After calculating the kWh saved, the specific facility's average cost per kilowatt hour shall be used to determine <br />dollar savings. <br />(kWh saved) x (average kWh rate) = $ kWh saved <br />($ kWh saved) = Total dollars saved <br />Operational Savings <br />The Purchaser will realize maintenance and operational savings resulting from the new system installations, <br />extended warranties, and/or service agreements provided by Climatec LLC. The operational savings are agreed to <br />be met upon the completed installation of the energy retrofit contract. <br />Pre Retrofit Measurements <br />None required for this FEM. <br />Post Retrofit Measurements <br />None required for this FEM. <br />Adjustments <br />None required for this FEM. <br />Attachment A <br />*CLIMATEC' Page 10 of 13 <br />MFRGING BUIL-DINGO & TFC.HNQL_LK!v <br />
The URL can be used to link to this page
Your browser does not support the video tag.