My WebLink
|
Help
|
About
|
Sign Out
Home
4A Public Hearings 2016 1121
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2016
>
Packet 2016 1121
>
4A Public Hearings 2016 1121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2016 5:07:38 PM
Creation date
11/16/2016 5:07:30 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
11/21/2016
Retention
PERM
Document Relationships
Reso 2016-153
(Reference)
Path:
\City Clerk\City Council\Resolutions\2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and masonry <br />foundation walls that are laterally supported at the top and bottom shall be permitted to be designed <br />and constructed in accordance with this section. Prescriptive design of foundation walls shall not be <br />used for structures assigned to Seismic Design Category D, E or F. <br />SECTION 7-5-185: MODIFICATIONS TO ACI 318 <br /> <br />Section 1905.1 is amended to read as shown below and Sections 1905.1.9 thru 1905.1.11 is added <br />to Chapter 19 of the 2016 Edition of the California Building Code: The last paragraph of Section 1905.1.2 of the 2016 Edition of the California Building Code is <br />amended to read as follows: <br /> <br />All special moment frames and special structural walls shall also satisfy 21.1.3 through 21.1.7. Concrete tilt-up wall panels classified as intermediate precast structural wall system shall satisfy 21.9 in addition to 21.4.2 and 21.4.3 for structures assigned to Seismic Design Category D, E or F. <br /> <br />1905.1.7 ACI 318, section 14.1.4 Delete ACI 318, section 14.1.4 and replace with the following: <br /> 1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following: <br /> <br />14.1.4 – Plain concrete in structures assigned to Seismic Design Category C, D, E or F. <br />14.1.4.1 – Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows: (a) Isolated footing of plain concrete supporting pedestals or columns are permitted, <br />provided the projection of the footing beyond the face of the supported member <br />does not exceed the footing thickness. <br /> Exception: In detached one–and two–family dwellings three stories or less in height, the projection of the footing beyond the face of the supported member <br />is permitted to exceed the following thickness. <br /> <br />(b) Plain concrete footing supporting walls are permitted, provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No.4 and shall have a total area of not less than 0.002 times the gross cross-sectional <br />area of the footing. A minimum of one bar shall be provided at the top and bottom <br />of the footing. Continuity of reinforcement shall be provided at corners and <br />intersections. <br />Sections 1905.1.9 through 1905.1.11 are added as follows: <br /> 1905.1.9 ACI 318, Section 18.7.5.. Modify ACI 318, Section 18.7.5, by adding Section 18.7.5.8 and 18.7.5.9 as follows: <br />18.7.5.8 Where the calculated point of contraflexure is not within the middle half of the member <br />clear height, provide transverse reinforcement as specified in ACI 318 Sections 18.7.5.1, Items (a)
The URL can be used to link to this page
Your browser does not support the video tag.