My WebLink
|
Help
|
About
|
Sign Out
Home
4A Public Hearings 2016 1121
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2016
>
Packet 2016 1121
>
4A Public Hearings 2016 1121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2016 5:07:38 PM
Creation date
11/16/2016 5:07:30 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
11/21/2016
Retention
PERM
Document Relationships
Reso 2016-153
(Reference)
Path:
\City Clerk\City Council\Resolutions\2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
File Number: 16-629 <br />2. Two-story buildings with a maximum plan dimension not exceeding 50 feet (15240 <br />mm) may have braced wall lines supported on continuous foundations at the <br />exterior walls only, provided: <br />a. Cripple walls do not exceed 4 feet (1219 mm) in height. <br />b. Where the first story is supported on a raised wood framed floor, the interior <br />braced wall panels are directly supported by either doubled joists, <br />continuous 4x blocking or minimum 4x floor beams. <br />Section 7-5-195: REPAIRS. Title 24, California Existing Building Code, Part 10, Section <br />404 is amended as follows <br /> <br />Sections 404.2.4 through 404.2.4.2 and Tables 404.2.4.1 and 404.2.4.2 are added as <br />follows: <br /> <br />404.2.4 Seismic Evaluation and Design Procedures for Repairs. The seismic evaluation <br />and design shall be based on the procedures specified in the California Building Code, ASCE <br />31 Seismic Evaluation of Existing Buildings (for evaluation only) or ASCE 41 Seismic <br />Rehabilitation of Existing Buildings. The procedures contained in Appendix A of the <br />International Existing Building Code shall be permitted to be used as specified in Section <br />3405.5.1.1.3. <br />404.2.4.1 Compliance with CBC level seismic forces. Where compliance with the seismic <br />design provisions of the California Building Code is required, the procedures shall be in <br />accordance with one of the following: <br />1. One-hundred percent of the values in the California Building Code. Where the existing <br />seismic force-resisting system is a type that can be designated as “Ordinary,” the values of R, <br />Ωo, and Cd used for analysis in accordance with Chapter 16 of the California Building Code <br />shall be those specified for structural systems classified as “Ordinary” in accordance with <br />Table 12.2-1 of ASCE 7, unless it is demonstrated that the structural system will provide <br />performance equivalent to that of a “Detailed,” “Intermediate” or “Special” system. <br />2. Compliance with ASCE 41 using both BSE-1 and BSE-2 earthquake hazard levels and the <br />corresponding performance levels in Table 404.2.4.1. <br />TABLE 404.2.4.1- Please see attachment A <br />PERFORMANCE CRITERIA FOR CBC LEVEL SEISMIC FORCES <br />404.2.4.2 Compliance with reduced CBC level seismic forces. Where seismic evaluation <br />and design is permitted to meet reduced California Building Code seismic force levels, the <br />procedures used shall be in accordance with one of the following: <br />1. The California Building Code using 75 percent of the prescribed forces. Values of R, Ωo, <br />and Cd used for analysis shall be as specified in Section 3405.2.4.1 Item 1. <br />Page 12 City of San Leandro Printed on 11/15/2016