My WebLink
|
Help
|
About
|
Sign Out
Home
5B Public Hearings 2019 0715
CityHall
>
City Clerk
>
City Council
>
Agenda Packets
>
2019
>
Packet 2019 0715
>
5B Public Hearings 2019 0715
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/9/2019 10:18:50 PM
Creation date
7/9/2019 10:16:14 PM
Metadata
Fields
Template:
CM City Clerk-City Council
CM City Clerk-City Council - Document Type
Agenda
Document Date (6)
7/15/2019
Retention
PERM
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
SECOND- FOURTH FLOOR - FIRE APPARATUS ACCESSPROPERTY LINE <br />PROPERTY LINE PROPERTY LINEPROPERTY LINENFPA 13 SPRINKLER SYSTEM TO BE USEDLINE OF PARKINGLINE OF PARKINGCENTER LINE OF STREETCENTER LINE OF STREETR28'-0"26 FT. WIDE FIRE TRUCK CLEARANCE24'-41 <br />4" <br />NEAR WALL <br />22'-101 <br />2" <br />NEAREST WALL <br />17'-9" <br />9'-0" <br />LINE OF PARKING <br />LINE OF PARKING <br />25'-1" <br />TO OUTSIDE EDGE OF PARKING <br />28'-10" <br />FURTHEST WALL <br />24'-41 <br />4" <br />NEAR WALL <br />22'-101 <br />4" <br />NEAREST WALL <br />24'-41 <br />4" <br />WINDOW WALL <br />28'-10" <br />FURTHEST BEDROOM WINDOW <br />24'-7" <br />NEAR WALL <br />29'-93 <br />4" <br />FURTHEST BEDROOM WINDOWGROUND FLOOR - FIRE APPARATUS ACCESSPROPERTY LINE PROPERTY LINE PROPERTY LINEPROPERTY LINEOPEN STAIR STRAIGHTRUN STAIR ACCESS TOSECOND LEVEL DECK ANDGATE WITH KNOX BOXNFPA 13 SPRINKLER SYSTEM TO BE USEDUP1 2 37 6 589111213101617181920212223242526UPCBA1514427UPUP3080 DRCGRWASHINGTON AVENUEPARROTT STREETP5P4P3P2P1LINE OF PARKINGLINE OF PARKINGCENTER LINE OF STREETCENTER LINE OF STREETR28'-0"26 FT. WIDE FIRE TRUCK CLEARANCEFDC25'-6"COLUMNS26'-3"STOREFRONT WINDOWS OPEN STAIRSTRAIGHT RUNACCESS TOSECOND LEVELDECK26'-0"17'-9"9'-0"KNOXBOXNO PARKING AT LOCATIONIN FRONT OF PUMP ROOMLINE OF PARKING <br />LINE OF PARKING STRAIGHT RUN FIREACCESS TO SECONDLEVEL DECK10'-0"8'-0"DOOR ACCESSGARAGE PARKINGBELOWSECOND LEVELDECKPARROTT STREETSIDEWALKLINE OF GUARDRAILWALL AT PROPERTY LINEBEHIND1A0 5.1SECTION AT WEST STAIR1A0 5.11A0 5.1A1A3.1A1A3.1DOOR WITHKNOX BOX23'-1"ENTRY COLUMNS26'-612"ENTRY STORFRONT26'-612"STORFRONT25'-6"COLUMNS25'-6"WALL29'-934"STAIR ACCESS WALL28'-11"COMMERCIAL WALL <br />23'-01 <br />2" <br />ENTRY COLUMN <br />21'-31 <br />4" <br />BALCONY <br />21'-31 <br />4" <br />BALCONY <br />26'-0"OPEN STAIRSTRAIGHT RUNACCESS TOSTREET LEVELOPEN STAIR STRAIGHTRUN STAIR ACCESS TOSTREET LEVEL26'-0"26'-0"FIRE SAFETY NOTES1. A LIFE SAFETY FIRE ALARM SYSTEM SHALL BE PROVIDED THROUGHOUT THE BUILDING2. A FIRE ALARM SYSTEM SHALL BE INSTALLED AS OUTLINED IN THE 2016 CALIFORNIA FIRE CODE3. RESIDENTIAL UNITS ARE REQUIRED TO HAVE SMOKE DETECTORS AND CARBON MONOXIDEDETECTORS AS OUTLINED IN THE CALIFORNIA BUILDING CODE AND CALIFORNIA FIRE CODE4. THE BUILDING SHALL BE EQUIPPED WITH AN EMERGENCY RESPONDER RADIO COVERAGE SYSTEM ASOUTLINED IN SECTION 510.1 OF THE 2016 CALIFORNIA FIRE CODEC H U N T H A L E J O N E S A R C H I T E C T S444 Spear Street, Suite 105San Francisco, CA 94105www.hunthalejones.comt. 415-512-1300f. 415-288-0288DATE:PROJECT:268 PARROTT STREETSAN LEANDRO, CA01.03.2019335006SCALE:FIRE SAFETY DESIGN ANALYSIS _FIRE APPARATUS ACCESSNTS52
The URL can be used to link to this page
Your browser does not support the video tag.