Laserfiche WebLink
FIRST FLOOR - TRAVEL DISTANCESSECOND FLOOR - TRAVEL DISTANCETHIRD FLOOR - TRAVEL DISTANCEFOURTH FLOOR - TRAVEL DISTANCECOMMON PATH: 75 FT.EXIT ACCESS: (E2: 128 FT.) + (C: 75 FT.) = 198 FT.EXITING - PATH OF TRAVELCOMMON PATH: 90 FT.EXIT ACCESS: 111 FT. + (C: 90 FT.) = 201 FT. TOTALEXIT ACCESS 65 FT.+ (C: 90 FT.)= 175 FT. TOTALEXIT DISCHARGE: 3 FT.EXIT DISCHARGE: 16 FT.EXIT DISCHARGE: 12 FT.EXIT ACCESS: (E1: 116 FT.) + (C: 75 FT.) = 191 FT.COMMON PATH: 73 FT.COMMON PATH: 73 FT.EXIT ACCESS: (S: 21 FT.) + (E2: 25 FT.) + (C: 73 FT.) = 119 FT.EXIT ACCESS: (E1: 128 FT.) + (C: 73 FT.) = 201 FT.EXIT ACCESS: (S: 47 FT.) + (E2: 25 FT.) + (C: 73 FT.) = 145 FT.EXIT ACCESS: (E1: 128 FT.) + (C: 73 FT.) = 201 FT.EXIT 1EXIT 2EXIT 2EXIT 1EXIT 1EXIT 1 SPECIAL PROVISIONS, PER CBC CHAPTER 4S-2, PER CBC SEC. 406MOTOR VEHICLE RELATED PER OCCUPANCYSEPARATION, CBC 508, TABLE 508.4R-2, PER CBC SEC. 420WALLS SEPARATING UNITS - 1 HR. FIRE PARTITION,PER CBC 708FLOORS SEPARATING UNITS - 1 HR., PER CBC 711OCCUPANCY SEPARATION, PER CBC SEC. 508 & TABLE 508.1M to S-2 1 HR.M to R-2 1 HR.S-2 to R-2 1 HR.1. SPRINKLEDNFPA 13 SPRINKLER SYSTEM TO BE USED2. OCCUPANCIESM MERCANTILES-2 GARAGER-2 MULTIFAMILY RESIDENTIAL3.CONSTRUCTION TYPETYPE VA - RATED WOOD FRAME4. RATED CONSTRUCTIONCONSTRUCTION TYPETYPE VA, PER CBC TABLE 601 1 HR @: STRUCTURALFRAMEMS-2R-2< 5 FT.2 HR.1 HR.1 HR.5 FT ≤ X < 10 FT.1 HR.1 HR.1 HR.10 FT. ≤ X < 30 FT.1 HR.1 HR.1 HR.X ≥ 30 FT.000AREA SEPARATIONNOT REQUIRED, SEE PART 6SHAFT CONSTRUCTION, PER CBC SEC. 7132 HR. WHEN CONNECTING 4 STORIES OR MORE* NOT LESS THAN FLOOR ASSEMBLY PENETRATED1 HR. WHEN CONNECTION LESS THAN 4 STORIES5.ALLOWABLE OPENINGSPER CBC TABLE 705.80 TO LESS THAN 3 FT.: NOT PERMITTED3 TO LESS THAN 5 FT.:15%5 TO LESS THAN 10 FT.:25%10 TO LESS THAN 15 FT.:45%15 TO LESS THAN 20 FT.:75%20 OR GREATER:UNLIMITED6.ALLOWABLE BUILDING HEIGHT AND AREAM OCCUPANCY70 FT., 4 STORIES AND 42,000 SQ. FT / 1 STORYPROVIDEDS-2 OCCUPANCY70 FT., 5 STORIES AND 63,000 SQ. FT. / 1 STORYPROVIDEDR-2 OCCUPANCY70 FT., 4 STORIES AND 36,000 SQ. FT. / 4 STORIESPROVIDED7. EXISTINGOCCUPANCY LOADM OCCUPANCY2,563 / 60 = 42S OCCUPANCY10,459 / 200 = 52R OCCUPANCY31,287 / 200 = 156REQUIRED EXITS2 EXITS REQ'D @ OCCUPANT LOAD LESS THAN 500COMMON PATHM - 75 FT.PER TABLE 1006.2.1S-2 - 100 FT.R-2 - 125 FT.EXIT ACCESSM - 250 FT.PER TABLE 1017.2S-2 - 400 FT.R-2 - 250 FT.* SEE EXITING DIAGRAMS FOR DISTANCES8.ACCESSIBILITYALL SPACES AND RESIDENTIAL UNITS EXCEPT UNOCCUPIED ROOF, TO BEACCESSIBLE PER CBC CHAPTER 11ABUILDING CODE SUMMARYUNIT 209UNIT 208UNIT 207UNIT 205UNIT 204UNIT 203UNIT 201UNIT 202UNIT 309UNIT 308UNIT 307UNIT 305UNIT 304UNIT 303UNIT 301UNIT 302UNIT 409UNIT 408UNIT 407UNIT 405UNIT 404UNIT 403UNIT 401UNIT 402UNIT 306UNIT 406FIRE SAFETY NOTES1. A LIFE SAFETY FIRE ALARM SYSTEM SHALL BE PROVIDED THROUGHOUT THE BUILDING2. A FIRE ALARM SYSTEM SHALL BE INSTALLED AS OUTLINED IN THE 2016 CALIFORNIA FIRECODE3. RESIDENTIAL UNITS ARE REQUIRED TO HAVE SMOKE DETECTORS AND CARBONMONOXIDE DETECTORS AS OUTLINED IN THE CALIFORNIA BUILDING CODE ANDCALIFORNIA FIRE CODE4. THE BUILDING SHALL BE EQUIPPED WITH AN EMERGENCY RESPONDER RADIOCOVERAGE SYSTEM AS OUTLINED IN SECTION 510.1 OF THE 2016 CALIFORNIA FIRECODEC H U N T H A L E J O N E S A R C H I T E C T S444 Spear Street, Suite 105San Francisco, CA 94105www.hunthalejones.comt. 415-512-1300f. 415-288-0288DATE:PROJECT:268 PARROTT STREETSAN LEANDRO, CA01.03.2019335006SCALE:PROJECT SCOPE AND SUMMARYNTSAttachments - F-J51